1. Possible Causes
_______________
- ADIRU-2 (1FP2)
- wiring of the ADR OUTPUT BUS 2 bus from the ADIRU 2 (1FP2) to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 22-91-00-710-001 Ground Scanning of the AFS
AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3)
ASM 34-13/01
3. Fault Confirmation
__________________
A. Test Do the operational test of the ground scanning of the AFS (Ref. AMM TASK 22-91-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message AFS : ADIRU 2:
- replace the ADIRU-2 (1FP2) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring of the ADR OUTPUT BUS 2 bus from the ADIRU 2 (1FP2) to the first terminal block (Ref. ASM 34-13/01).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-13-00∞∞∞∞∞∞∞∞∞∞Page 277
Feb 01/05R
CES Loss of the ADR 2 BUS 2 Output Identified by the EFCS 1
1. Possible Causes
_______________
- ADIRU-2 (1FP2)
- wiring of the ADR OUTPUT BUS 2 bus from the ADIRU 2 (1FP2) to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning) AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3) AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3) ASM 34-13/01
3. Fault Confirmation
__________________
A. Test Do the BITE test of the EFCS (ground scanning) (system 1) (Ref. AMM TASK 27-96-00-740-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message ADR2 BUS 2:
- replace the ADIRU-2 (1FP2) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring of the ADR OUTPUT BUS 2 bus from the ADIRU 2 (1FP2) to the first terminal block (Ref. ASM 34-13/01).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-13-00∞∞∞∞∞∞∞∞∞∞Page 278
Feb 01/05R
CES Loss of the ADR 2 BUS 2 Output Identified by the ATC 2
1. Possible Causes
_______________
- ADIRU-2 (1FP2)
- wiring of the ADR OUTPUT BUS 2 bus from the ADIRU 2 (1FP2) to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-52-00-740-004 BITE Test of the ATC
ASM 34-13/01
3. Fault Confirmation
__________________
A. Test Do the BITE test of the ATC (system 2) (Ref. AMM TASK 34-52-00-740-004).
4. Fault Isolation
_______________
**ON A/C 001-049, 101-105, 151-199, 211-220,
A. If the test gives the maintenance message ATC 2 : NO DATA FROM ADIRU:
- replace the ADIRU-2 (1FP2) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 导航 NAVIGATION 1(79)