1. Possible Causes
_______________
- ADIRU-3 (1FP3)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-60-00-740-002 EIS Input Test
AMM 31-60-00-740-007 GROUND SCANNING Test of the DMC
AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3)
3. Fault Confirmation
__________________
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
A. Test Do the EIS input test (system 3) (Ref. AMM TASK 31-60-00-740-002).
R **ON A/C 106-149, 303-399, 401-499,
A. Test Do the Ground Scanning Test of the DMC (system 3) (Ref. AMM TASK 31-60-00-740-007).
**ON A/C ALL
4. Fault Isolation
_______________
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
A. If the test gives the maintenance message DMC 3 : NO ADC 3 DATA:
- replace the ADIRU-3 (1FP3) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
R **ON A/C 106-149, 303-399, 401-499,
A. If the test gives the maintenance message ADIRU3(1FP3)BUSX ADR/DMC3(1WT3)
- replace the ADIRU-3 (1FP3) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
**ON A/C ALL
B. Do the test given in Para. 3.
Loss of the ADR 1 BUS 2 Output Identified by the ECAM 2
1. Possible Causes
_______________
- ADIRU-1 (1FP1)
- wiring of the ADR OUTPUT BUS2 bus from the ADIRU1 (1FP1) to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 31-50-00-710-001 Ground Scanning of the Central Warning System
AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3)
ASM 34-13/01
3. Fault Confirmation
__________________
A. Test Do the operational test of the central warning systems (system 2) (Ref. AMM TASK 31-50-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message FWC2 : NO DATA FROM ADC1:
- replace the ADIRU-1 (1FP1), (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring of the ADR OUTPUT BUS2 bus from the ADIRU1 (1FP1) to the first terminal block, (Ref. ASM 34-13/01).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-13-00∞∞∞∞∞∞∞∞∞∞Page 220
Feb 01/05R
CES Loss of the ADR 1 BUS 2 Output Identified by the AFS
1. Possible Causes
_______________
- ADIRU-1 (1FP1)
- wiring of the ADR OUTPUT BUS 2 bus from the ADIRU1 (1FP1) to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 22-91-00-710-001 Ground Scanning of the AFS
AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3)
ASM 34-13/01
3. Fault Confirmation
__________________
A. Test Do the operational test of the ground scanning of the AFS (Ref. AMM TASK 22-91-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message AFS : ADIRU1:
- replace the ADIRU-1 (1FP1), (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring of the ADR OUTPUT BUS 2 bus from the ADIRU1 (1FP1) to the first terminal block, (Ref. ASM 34-13/01).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-13-00∞∞∞∞∞∞∞∞∞∞Page 221