3. Fault Confirmation
__________________
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
A. Test Do the EIS input test (system 1) (Ref. AMM TASK 31-60-00-740-002).
R **ON A/C 106-149, 303-399, 401-499,
A. Test Do the Ground Scanning Test of the DMC (system 1) (Ref. AMM TASK 31-60-00-740-007).
**ON A/C ALL
4. Fault Isolation
_______________
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
A. If the test gives the maintenance message DMC1 : NO ADC1 DATA:
- replace the ADIRU-1 (1FP1), (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
R **ON A/C 106-149, 303-399, 401-499,
A. If the test gives the maintenance message ADIRU3(1FP3)BUSX ADR/DMC1(1WT1)
- replace the ADIRU-1 (1FP1), (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
**ON A/C ALL
B. Do the test given in Para. 3.
TASK 34-13-00-810-803 Internal Failure of the ADR 1 Identified by the ECAM 2
1. Possible Causes
_______________
- ADIRU-1 (1FP1)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-50-00-710-001 Ground Scanning of the Central Warning System
AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3)
3. Fault Confirmation
__________________
A. Test Do the operational test of the central warning systems (system 2) (Ref. AMM TASK 31-50-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message FWC2 : NO DATA FROM ADC1:
- replace the ADIRU-1 (1FP1), (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-13-00∞∞∞∞∞∞∞∞∞∞Page 204
Feb 01/05R
CES TASK 34-13-00-810-804 Internal Failure of the ADR 1 Identified by the EFCS 1
1. Possible Causes
_______________
- ADIRU-1 (1FP1)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning) AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3) AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3)
3. Fault Confirmation
__________________
A. Test Do the BITE test of the EFCS (Ground Scanning) (system 1) (Ref. AMM TASK 27-96-00-740-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message ADR1:
- replace the ADIRU-1 (1FP1), (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-13-00∞∞∞∞∞∞∞∞∞∞Page 205
Feb 01/05R
CES TASK 34-13-00-810-805 Internal Failure of the ADR 1 Identified by the ECAM 1
1. Possible Causes
_______________
- ADIRU-1 (1FP1)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-50-00-710-001 Ground Scanning of the Central Warning System
AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3)
3. Fault Confirmation
__________________
A. Test Do the operational test of the central warning systems (system 1) (Ref. AMM TASK 31-50-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message FWC1 : NO DATA FROM ADC1:
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 导航 NAVIGATION 1(59)