1. Possible Causes
_______________
- ADIRU-1 (1FP1)
- wiring of the ADR OUTPUT BUS 2 bus from the ADIRU 1 (1FP1) to the first terminal block
- wiring between the terminal blocks 1512VT and 1860VT
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 27-96-00-740-001 BITE Test of the EFCS (Ground Scanning)
AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-14-00-740-001 Interface Test of the IR
ASM 34-13/01
AWM 34-11-18
3. Fault Confirmation
__________________
A. Test Do the BITE test of the EFCS (Ground Scanning) (system 1) (Ref. AMM TASK 27-96-00-740-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message ADR1 BUS 2:
- do the interface test of the IR (system 2) (Ref. AMM TASK 34-14-00-740-001).
(1) If the test gives the maintenance message ADIRU1 (1FP1)/ADIRU2 (1FP2):
- replace the ADIRU-1 (1FP1) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
(a) If the fault continues:
- do a check and repair the wiring of the ADR OUTPUT BUS 2 bus from the ADIRU 1 (1FP1) to the first terminal block, (Ref. ASM 34-13/01).
(2) If the test does not give the maintenance message ADIRU1 (1FP1)/ADIRU2 (1FP2):
- do a check and repair the wiring between the terminal blocks 1512VT and 1860VT: between pins 15X, 15Y and 28N, 27N (Ref. AWM 34-11-18).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-13-00∞∞∞∞∞∞∞∞∞∞Page 222
Feb 01/05R CES
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-13-00∞∞∞∞∞∞∞∞∞∞Page 223
Feb 01/05R
CES Loss of the ADR 1 BUS 2 Output Identified by the IR 2
1. Possible Causes
_______________
- ADIRU-1 (1FP1)
- wiring of the ADR OUTPUT BUS 2 bus from the ADIRU 1 (1FP1) to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-14-00-740-001 Interface Test of the IR
ASM 34-13/01
3. Fault Confirmation
__________________
A. Test Do the Interface test of the IR (system 2) (Ref. AMM TASK 34-14-00-740-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message ADIRU1 (1FP1)/ADIRU2 (1FP2):
- replace the ADIRU-1 (1FP1), (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring of the ADR OUTPUT BUS 2 bus from the ADIRU 1 (1FP1) to the first terminal block, (Ref. ASM 34-13/01).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-13-00∞∞∞∞∞∞∞∞∞∞Page 224
Feb 01/05R
CES Loss of the ADR 1 BUS 2 Output Identified by the SFCC 2
1. Possible Causes
_______________
- ADIRU-1 (1FP1)
- wiring of the ADR OUTPUT BUS 2 bus from the ADIRU 1 (1FP1) to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 27-54-00-710-001 Operational Test of the Flap System
AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3)