(a) If there is continuity:
- replace the ADM2 (Ref. AMM TASK 34-11-17-000-001) and (Ref. AMM TASK 34-11-17-400-001)
- install the ADIRU2.
(b) If there is no continuity:
- get access to the ADM-R STATIC PRESSURE (19FP6) and the ADM-L STATIC PRESSURE (19FP7) (Ref. AMM TASK 34-11-17-000-001) (Para. 2.B.)
- disconnect the electrical connector of the ADM6 and make sure that there is no continuity between pins A/A, C, between pins A/C, E and between pins A/A, E of the ADM6.
1_ If there is continuity:
- replace the ADM6 (Ref. AMM TASK 34-11-17-000-001) and (Ref.
AMM TASK 34-11-17-400-001)
- connect the electrical connector of the ADM1
- install the ADIRU2.
2 If there is no continuity:
_
- disconnect the electrical connector of the ADM7 and make sure that there is no continuity between pins A/A, C, between pins A/C, E and between pins A/A, E of the ADM7.
a If there is continuity:
_
- replace the ADM7
- connect the electrical connector of the ADM2 and 6
- install the ADIRU2.
b If there is no continuity:
_
- do a check and repair the aircraft wiring between ADIRU2 pins AA/6G, 6H, 6J and the related LRU (Ref. ASM 34-13/03)
- connect the electrical connector of the ADM
- install the ADIRU2.
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 101-105, 151-199, 201-210, ∞∞34-11-00∞∞∞∞∞∞∞∞∞∞Page A239
301-399, 401-499, Aug 01/05 CES
Failure of the ADM Power Supply of the ADIRU3
1. Possible Causes
_______________
- ADIRU-3 (1FP3)
- ADM-STBY TOTAL PRESSURE (19FP3)
- ADM-STBY STATIC PRESSURE (19FP8)
- aircraft wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 34-11-17-000-001 Removal of the Air Data Module (19FP1,19FP2,19FP3,19FP4,19FP5,19FP6, 19FP7,19FP8) AMM 34-11-17-400-001 Installation of the Air Data Module
(19FP1,19FP2,19FP3,19FP4,19FP5,19FP6, 19FP7,19FP8) AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3) AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3) AMM 34-13-00-740-002 INTERFACE TEST of the ADR ASM 34-13/03
3. Fault Confirmation
__________________
A. Test Do the Interface test of the ADR (system 3) (Ref. AMM TASK 34-13-00-740-002).
4. Fault Isolation
_______________
A. If the test gives the maintenance message ADM3 (19FP3)/ ADM8 (19FP8):
- remove the ADIRU-3 (1FP3) (Ref. AMM TASK 34-12-34-000-001)
- make sure that there is no continuity between pins AA/6G, 6H, between pins AA/6H, 6J and between pins AA/6G, 6J of the rack connector.
(1) If there is no continuity:
- install a new ADIRU3 (Ref. AMM TASK 34-12-34-400-001).
(2) If there is continuity:
- get access to the ADM-STBY TOTAL PRESSURE (19FP3) (Ref. AMM TASK 34-11-17-000-001) (Para. 2.B.)
- disconnect the electrical connector of the ADM3 and make sure that there is no continuity between pins A/A, C, between pins A/C, E and between pins A/A, E of the ADM3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 101-105, 151-199, 201-210, ∞∞34-11-00∞∞∞∞∞∞∞∞∞∞Page A240
301-399, 401-499, Aug 01/05 CES
(a) If there is continuity:
- replace the ADM3 (Ref. AMM TASK 34-11-17-000-001) and (Ref. AMM TASK 34-11-17-400-001)
- install the ADIRU3.
(b) If there is no continuity:
- get access to the ADM-STBY STATIC PRESSURE (19FP8) (Ref. AMM TASK 34-11-17-000-001) (Para. 2.B.)
- disconnect the electrical connector of the ADM8 and make sure that there is no continuity between pins A/A, C, between pins A/C, E and between pins A/A, E of the ADM8.
1_ If there is continuity:
- replace the ADM8 (Ref. AMM TASK 34-11-17-000-001) and (Ref.
AMM TASK 34-11-17-400-001)
- connect the electrical connector of the ADM3
- install the ADIRU3.
2_ If there is no continuity: