(b) Conclusion Remove the Angle of Attack sensor that exceeds these tolerances (Ref. AMM TASK 34-11-19-000-001) and (Ref. AMM TASK 34-11-19-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-11-00∞∞∞∞∞∞∞∞∞∞Page A209
May 01/05R
CES No AOA Test Activation
1. Possible Causes
_______________
- ADIRU-1 (1FP1)
- SENSOR-ANGLE OF ATTACK, 1 (3FP1)
- ADIRU-2 (1FP2)
- SENSOR-ANGLE OF ATTACK, 2 (3FP2)
- ADIRU-3 (1FP3)
- SENSOR-ANGLE OF ATTACK, 3 (3FP3)
- RELAY-AOA 1 TEST (21FP1)
- wiring of the AOA 1 TEST relay (21FP1)
- wiring of the ground signal at angle of attack sensor 1 (3FP1)
- RELAY-AOA 2 TEST (21FP2)
- wiring of the AOA 2 TEST relay (21FP2)
- wiring of the ground signal at angle of attack sensor 2 (3FP2)
- RELAY-AOA 3 TEST (21FP3)
- wiring of the AOA 3 TEST relay (21FP3)
- wiring of the ground signal at angle of attack sensor 3 (3FP3)
- wiring from the ADIRS/ADIRU/3SWTG/SPLY circuit breaker (9FP) to the first terminal block
- C/B-ADIRS/ADIRU/3SWTG/SPLY circuit breaker (9FP)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 34-10-00-710-007 Test of the Angle of Attack Warning AMM 34-11-19-000-001 Removal of the Angle of Attack Sensor (3FP1, 3FP2, 3FP3) AMM 34-11-19-400-001 Installation of the Angle of Attack Sensor (3FP1,
3FP2, 3FP3)
AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3)
ASM 34-11/01
ASM 34-11/02
3. Fault Confirmation
__________________
A. Test
(1) Do the test of the angle of attack warning (Ref. AMM TASK 34-10-00-710-007).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-11-00∞∞∞∞∞∞∞∞∞∞Page A210
May 01/05R CES
4. Fault Isolation
_______________
A. Table of the circuit breakers used in this procedure:
-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
**ON A/C 001-049, 051-061, 101-105, 201-203,
121VU ADIRS/ADIRU/3PWR/SWTG 9FP N10
R **ON A/C 062-099, 106-149, 151-199, 204-299, 301-399, 401-499,
121VU ADIRS/ADIRU/3PWR/SWTG 9FP N09
**ON A/C ALL
B. If you cannot start the test of the angle of attack sensor 1 on the MCDU:
- replace the ADIRU-1 (1FP1) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
(1) If the fault continues:
- replace the RELAY-AOA 1 TEST (21FP1)
(a) If the fault continues:
- do a check of the wiring of the AOA 1 TEST relay (21FP1): . from pin A/A to the first terminal block . from pin A/X to the first terminal block . from pin A/Z to ADIRU1 (1FP1) pin AA/12G . from pin A/2 to angle of attack sensor 1 (3FP1) pin A/X (Ref. ASM 34-11/02).
1 If there is no continuity:
_ - repair the above wiring.
2 If there is continuity:
_
- do a check of the wiring of the ground signal at angle of attack sensor 1 (3FP1) pin A/V (Ref. ASM 34-11/02).
a If there is no continuity:
_ - repair the above wiring.
b If there is continuity:
_
- replace the SENSOR-ANGLE OF ATTACK, 1 (3FP1) (Ref. AMM TASK 34-11-19-000-001) and (Ref. AMM TASK 34-11-19-400-001).