Failure of the Pressure Transducer of the R Static Pressure ADM
1. Possible Causes
_______________
- ADM-R STATIC PRESSURE (19FP6)
- ADIRU-2 (1FP2)
- wiring between R static pressure ADM (19FP6) and the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 34-11-17-000-001 Removal of the Air Data Module (19FP1,19FP2,19FP3,19FP4,19FP5,19FP6, 19FP7,19FP8) AMM 34-11-17-400-001 Installation of the Air Data Module
(19FP1,19FP2,19FP3,19FP4,19FP5,19FP6, 19FP7,19FP8) AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3) AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3) AMM 34-13-00-740-002 INTERFACE TEST of the ADR AWM 34-11-10
3. Fault Confirmation
__________________
A. Test Do the Interface test of the ADR (system 2) (Ref. AMM TASK 34-13-00-740-002).
4. Fault Isolation
_______________
A. If the test gives the maintenance message ADM6 (19FP6):
- replace the ADM-R STATIC PRESSURE (19FP6) (Ref. AMM TASK 34-11-17-000-001) and (Ref. AMM TASK 34-11-17-400-001).
(1) If the fault continues:
- replace the ADIRU-2 (1FP2) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
(a) If the fault continues:
- do a check and repair the wiring between R static pressure ADM (19FP6) and the first terminal block pins A, C, E/A (Ref. AWM 34-11-10).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-11-00∞∞∞∞∞∞∞∞∞∞Page 223
May 01/04R CES
Failure of the Pressure Transducer of the Standby Total Pressure ADM
1. Possible Causes
_______________
- ADM-STBY TOTAL PRESSURE (19FP3)
- ADIRU-3 (1FP3)
- wiring between standby total pressure ADM (19FP3) and the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 34-11-17-000-001 Removal of the Air Data Module (19FP1,19FP2,19FP3,19FP4,19FP5,19FP6, 19FP7,19FP8) AMM 34-11-17-400-001 Installation of the Air Data Module
(19FP1,19FP2,19FP3,19FP4,19FP5,19FP6, 19FP7,19FP8) AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3) AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3) AMM 34-13-00-740-002 INTERFACE TEST of the ADR ASM 34-13/03
3. Fault Confirmation
__________________
A. Test Do the Interface test of the ADR (system 3) (Ref. AMM TASK 34-13-00-740-002).
4. Fault Isolation
_______________
A. If the test gives the maintenance message ADM3 (19FP3):
- replace the ADM-STBY TOTAL PRESSURE (19FP3) (Ref. AMM TASK 34-11-17-000-001) and (Ref. AMM TASK 34-11-17-400-001).
(1) If the fault continues:
- replace the ADIRU-3 (1FP3) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
(a) If the fault continues:
- do a check and repair the wiring between standby total pressure ADM (19FP3) and the first terminal block pins A/A, C, E (Ref. ASM 34-13/03).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-11-00∞∞∞∞∞∞∞∞∞∞Page 224
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 导航 NAVIGATION 1(10)