Inability to know the SDI Code Related to the ADM3 and the ADM8
1. Possible Causes
_______________
- ADM-STBY TOTAL PRESSURE (19FP3)
- ADM-STBY STATIC PRESSURE (19FP8)
- SDI pin programming of the ADM (19FP3)
- SDI pin programming of the ADM (19FP8)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 34-11-17-000-001 Removal of the Air Data Module (19FP1,19FP2,19FP3,19FP4,19FP5,19FP6, 19FP7,19FP8) AMM 34-11-17-400-001 Installation of the Air Data Module
(19FP1,19FP2,19FP3,19FP4,19FP5,19FP6, 19FP7,19FP8) AMM 34-13-00-740-002 INTERFACE TEST of the ADR ASM 34-13/03
3. Fault Confirmation
__________________
A. Test Do the Interface test of the ADR (system 3) (Ref. AMM TASK 34-13-00-740-002).
4. Fault Isolation
_______________
A. If the test gives the maintenance message ADM3 (19FP3)/ ADM8 (19FP8):
- get access to the total pressure ADM (19FP3) (Ref. AMM TASK 34-11-17-000-001) (Para. 2.B.)
- disconnect the electrical connector of the ADM (19FP3)
- make sure that there is continuity between pins A/J, K, L, P and that there is an open circuit between pins A/M, N (Ref. ASM 34-13/03).
(1) If the pin programming is incorrect:
- repair the SDI pin programming of the ADM (19FP3)
- connect the electrical connector of the ADM (19FP3).
(2) If the pin programming is correct:
- get access to the static pressure ADM (19FP8) (Ref. AMM TASK 34-11-17-000-001) (Para. 2.B.)
- disconnect the electrical connector of the ADM (19FP8)
- make sure that there is continuity between pins A/J, K, L, M, N, P.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 051-099, 106-149, 204-299, 301-399, ∞∞34-11-00∞∞∞∞∞∞∞∞∞∞Page A231
401-499, Aug 01/05 CES
(a) If the pin programming is incorrect:
- repair the SDI pin programming of the ADM (19FP8)
- connect the electrical connectors of the ADM (19FP3) and ADM (19FP8).
(b) If the pin programming is correct:
- replace the ADM-STBY TOTAL PRESSURE (19FP3) (Ref. AMM TASK 34-11-17-000-001) and (Ref. AMM TASK 34-11-17-400-001).
- connect the electrical connector of the ADM (19FP8).
1 If the fault continues:
_
- replace the ADM-STBY STATIC PRESSURE (19FP8).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 051-099, 106-149, 204-299, 301-399, ∞∞34-11-00∞∞∞∞∞∞∞∞∞∞Page A232
401-499, Aug 01/05 CES
R **ON A/C 001-049, 101-105, 151-199, 201-210, 301-399, 401-499,
TASK 34-11-00-810-880
Loss of the ADM BUS Input to the ADIRU1
1. Possible Causes
_______________
- ADIRU-1 (1FP1)
- wiring between the ADIRU1 and the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-13-00-740-002 INTERFACE TEST of the ADR
ASM 34-13/03
3. Fault Confirmation
__________________
A. Test Do the Interface test of the ADR (system 1) (Ref. AMM TASK 34-13-00-740-002).
4. Fault Isolation
_______________
A. If the test gives the maintenance message
ADIRU1 (1FP1)/ WRG: ADM DC SUPPLY TO ADM:
- replace the ADIRU-1 (1FP1), (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
(1) If the fault continues:
- remove the ADIRU1
- do a check and repair the wiring between the ADIRU1 and the first terminal block: pins AA/6G, 6H, 6J of the ADIRU1 (Ref. ASM 34-13/03).
- install the ADIRU1.
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 101-105, 151-199, 201-210, ∞∞34-11-00∞∞∞∞∞∞∞∞∞∞Page A233
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 导航 NAVIGATION 1(48)