3. Fault Confirmation
__________________
A. Test Do the BITE test of the EFCS (ground scanning) (system 2) (Ref. AMM TASK 27-96-00-740-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message ADR1 BUS 3:
- do the interface test of the IR (system 3) (Ref. AMM TASK 34-14-00-740-001).
(1) If the test gives the maintenance message ADIRU1 (1FP1)/ADIRU3 (1FP3):
- replace the ADIRU-1 (1FP1) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
(a) If the fault continues:
- do a check and repair the wiring of the ADR OUTPUT BUS 3 bus from the ADIRU 1 (1FP1) to the first terminal block (Ref. ASM 34-13/01).
(2) If the test does not give the maintenance message ADIRU1 (1FP1)/ADIRU3 (1FP3):
- do a check and repair the wiring between the terminal blocks 1510VT and 1851VT: between pins 1X, 1Y and 2E, 1E (Ref. AWM 34-11-21).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-13-00∞∞∞∞∞∞∞∞∞∞Page 254
Feb 01/05R CES
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-13-00∞∞∞∞∞∞∞∞∞∞Page 255
Feb 01/05R
CES TASK 34-13-00-810-851 Internal Failure of the ADR 2
1. Possible Causes
_______________
- ADIRU-2 (1FP2)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3) AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3) AMM 34-13-00-740-002 INTERFACE TEST of the ADR
3. Fault Confirmation
__________________
A. Test Do the Interface test of the ADR (system 2) (Ref. AMM TASK 34-13-00-740-002).
4. Fault Isolation
_______________
A. If the test gives the maintenance message ADIRU2 (1FP2):
- replace the ADIRU-2 (1FP2) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-13-00∞∞∞∞∞∞∞∞∞∞Page 256
Feb 01/05R
CES
TASK 34-13-00-810-852
Internal Failure of the ADR 2 Identified by the EIS 2
1. Possible Causes
_______________
- ADIRU-2 (1FP2)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-60-00-740-002 EIS Input Test
AMM 31-60-00-740-007 GROUND SCANNING Test of the DMC
AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3)
3. Fault Confirmation
__________________
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
A. Test Do the EIS input test (system 2) (Ref. AMM TASK 31-60-00-740-002).
R **ON A/C 106-149, 303-399, 401-499,
A. Test Do the Ground Scanning Test of the DMC (system 2) (Ref. AMM TASK 31-60-00-740-007).
**ON A/C ALL
4. Fault Isolation
_______________
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
A. If the test gives the maintenance message DMC 2 : NO ADC 2 DATA:
- replace the ADIRU-2 (1FP2) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
R **ON A/C 106-149, 303-399, 401-499,
A. If the test gives the maintenance message ADIRU2(1FP2)BUS1 ADR/DMC2(1WT2)
- replace the ADIRU-2 (1FP2) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 导航 NAVIGATION 1(73)