3. Fault Confirmation
__________________
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
A. Test Do the EIS input test (system 3) (Ref. AMM TASK 31-60-00-740-002).
R **ON A/C 106-149, 303-399, 401-499,
A. Test Do the Ground Scanning Test of the DMC (system 3) (Ref. AMM TASK 31-60-00-740-007).
**ON A/C ALL
4. Fault Isolation
_______________
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-302,
A. If the test gives the maintenance message DMC 3 : NO ADC 2 DATA :
- replace the ADIRU-2 (1FP2) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
R **ON A/C 106-149, 303-399, 401-499,
A. If the test gives the maintenance message ADIRU2(1FP2)BUS2 ADR/DMC3(1WT3)
- replace the ADIRU-2 (1FP2) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
**ON A/C ALL
B. Do the test given in Para. 3.
TASK 34-13-00-810-857
Internal Failure of the ADR 3 Identified by the ATC 1
1. Possible Causes
_______________
- ADIRU-3 (1FP3)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-52-00-740-004 BITE Test of the ATC
3. Fault Confirmation
__________________
A. Test Do the BITE test of the ATC (system 1) (Ref. AMM TASK 34-52-00-740-004).
4. Fault Isolation
_______________
**ON A/C 001-049, 101-105, 151-199, 211-220,
A. If the test gives the maintenance message ATC 1 : NO DATA FROM ADIRU:
- replace the ADIRU-3 (1FP3) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
R **ON A/C 051-099, 106-149, 201-210, 221-299, 301-399, 401-499,
A. If the test gives the maintenance message ADIRU 1/3 (1FP1/3)/ ATC1 (1SH1) :
- replace the ADIRU-3 (1FP3) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
**ON A/C ALL
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-13-00∞∞∞∞∞∞∞∞∞∞Page 264
Aug 01/05 CES TASK 34-13-00-810-858 Internal Failure of the ADR 2 Identified by the CFDS
1. Possible Causes
_______________
- ADIRU-2 (1FP2)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 31-32-00-869-002 Procedure for Class 3 Faults Reading
AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3)
3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU NAV PROBES/ADIRU 1/AND AOA 1/26VAC 5FP1 F07 49VU NAV PROBES/ADIRU1/115VAC 4FP1 F06 105VU ADIRS/ADIRU1/28VDC 6FP1 C02
B. Test On the CFDS MENU page, get access to the AVIONICS STATUS page (Ref. AMM TASK 31-32-00-869-002).
4. Fault Isolation
_______________
A. If the test gives the maintenance message NO ADR 2 DATA:
- replace the ADIRU-2 (1FP2) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
B. Do the test given in Para. 3.B.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-13-00∞∞∞∞∞∞∞∞∞∞Page 265
Feb 01/05R
CES TASK 34-13-00-810-861 Internal Failure of the ADR 2 Identified by the AFS
1. Possible Causes
_______________
- ADIRU-2 (1FP2)
2. Job Set-up Information