B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 051-099, 106-149, 204-299, 301-399, ∞∞34-11-00∞∞∞∞∞∞∞∞∞∞Page A250
401-499, Aug 01/05 CES
Air Data Portion of the ADIRU3 Unserviceable
1. Possible Causes
_______________
- ADIRU-3 (1FP3)
- ADM-STBY TOTAL PRESSURE (19FP3)
- ADM-STBY STATIC PRESSURE (19FP8)
- wiring between the ADIRU3 and the connector receptacle of the STBY total pressure ADM (19FP3)
- wiring between the connector receptacle of the STBY static pressure ADM (19FP8) and the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 34-11-17-000-001 Removal of the Air Data Module (19FP1,19FP2,19FP3,19FP4,19FP5,19FP6, 19FP7,19FP8) AMM 34-11-17-400-001 Installation of the Air Data Module
(19FP1,19FP2,19FP3,19FP4,19FP5,19FP6, 19FP7,19FP8) AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3) AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3) AMM 34-14-00-740-001 Interface Test of the IR ASM 34-13/03
3. Fault Confirmation
__________________
A. Do the interface test of the IR (system 3) (Ref. AMM TASK 34-14-00-740-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message ADIRU3 (1FP3) ADR BUS 1:
- swap the ADIRU-3 (1FP3) and the ADIRU1 (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
(1) If the fault stops:
- replace the ADIRU that you installed on side 1.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 051-099, 106-149, 204-299, 301-399, ∞∞34-11-00∞∞∞∞∞∞∞∞∞∞Page A251
401-499, Aug 01/05 CES
(2) If the fault continues:
- get access to the ADM-STBY TOTAL PRESSURE (19FP3) and ADM-STBY STATIC PRESSURE (19FP8) (Ref. AMM TASK 34-11-17-000-001) (Para. 2.A.)
- disconnect the electrical connector of the STBY total pressure ADM (19FP3) and make sure that there is +13.5V between pins A/C, A and -13.5V between pins A/C, E of the connector receptacle (Ref. ASM 34-13/03).
(a) If the voltages are not OK:
- do a check and repair the wiring between the ADIRU3 and the connector receptacle of the STBY total pressure ADM (19FP3): for pins AA/6G, 6H and 6J of the ADIRU3 and pins A/A, C and E of the connector receptacle
- connect the electrical connector of the STBY total pressure ADM (19FP3).
(b) If the voltages are OK:
- disconnect the electrical connector of the STBY static pressure ADM (19FP8) and make sure that there is +13.5V between pins A/C, A and -13.5V between pins A/C, E of the connector receptacle (Ref. ASM 34-13/03).
1_ If the voltages are not OK:
- do a check and repair the wiring between the connector
receptacle of the STBY static pressure ADM (19FP8) and the
first terminal block: for pins A/A, C and E of the connector
receptacle
- connect the electrical connectors of the STBY total pressure
ADM (19FP3) and the STBY static pressure ADM (19FP8).
2 If the voltages are OK and if the fault continues:
_
- replace the ADM-STBY TOTAL PRESSURE (19FP3) (Ref. AMM TASK 34-11-17-000-001) and (Ref. AMM TASK 34-11-17-400-001).
a If the fault continues :
_
- replace the ADM-STBY STATIC PRESSURE (19FP8).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 051-099, 106-149, 204-299, 301-399, ∞∞34-11-00∞∞∞∞∞∞∞∞∞∞Page A252
401-499, Aug 01/05 CES
R **ON A/C 001-049, 101-105, 151-199, 201-228, 301-399, 401-499,
TASK 34-11-00-810-892
Deterioration of the Angle of Attack Sensor 1
1. Possible Causes_______________
- SENSOR-ANGLE OF ATTACK, 1 (3FP1)
2. Job Set-up Information______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------