 **ON A/C ALL
 B. Do the test given in Para. 3.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-11-00∞∞∞∞∞∞∞∞∞∞Page 227
 May 01/05 CES Failure of the ADM Power Supply for the ADIRU 3


 1. Possible Causes
_______________
 - ADIRU-3 (1FP3)

 - wiring


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3)
 AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3)
 AMM 34-13-00-740-002 INTERFACE TEST of the ADR
 ASM 34-13/03

 3. Fault Confirmation
__________________
 A. Test Do the Interface test of the ADR (system 3) (Ref. AMM TASK 34-13-00-740-002).
 4. Fault Isolation
_______________
R **ON A/C 001-049, 101-105, 151-199, 201-203,
 A. If the test gives the maintenance messages ADM3 (19FP3)/ ADM8 (19FP8):
 - replace the ADIRU-3 (1FP3) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
 (1) If the fault continues:
 - do a check and repair the wiring between ADIRU 3 pins AA/6J, 6H, 6G and the first terminal block (Ref. ASM 34-13/03).
 **ON A/C ALL
 B. Do the test given in Para. 3.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-11-00∞∞∞∞∞∞∞∞∞∞Page 228
 May 01/05 CES Loss of the Angle of Attack Sensor 1


 1. Possible Causes
_______________
 - SENSOR-ANGLE OF ATTACK, 1 (3FP1)

 - wiring from angle of attack sensor 1 (3FP1) pins A/B,N to the ground terminal

 - wiring from angle of attack sensor 1 (3FP1) pins A/A,M to the first terminal block


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 34-11-19-000-001 Removal of the Angle of Attack Sensor (3FP1, 3FP2, 3FP3) AMM 34-11-19-400-001 Installation of the Angle of Attack Sensor (3FP1,
 3FP2, 3FP3)
 AMM 34-13-00-740-002 INTERFACE TEST of the ADR
 ASM 34-11/01

 3. Fault Confirmation
__________________
 A. Test Do the Interface test of the ADR (system 1) (Ref. AMM TASK 34-13-00-740-002).
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message AOA SENSOR1 (3FP1):
 - do a check for 26VAC at pins A/A,M of the angle of attack sensor 1 (3FP1).
 (1) If there is 26VAC:

 - replace the SENSOR-ANGLE OF ATTACK, 1 (3FP1) (Ref. AMM TASK 34-11-19-000-001) and (Ref. AMM TASK 34-11-19-400-001).

 (2) If there is no 26VAC:


 - do a check for a ground signal at pins A/B,N of the angle of attack sensor 1 (3FP1).
 (a) If there is no ground signal:
 - repair the wiring from angle of attack sensor 1 (3FP1) pins A/B,N to the ground terminal (Ref. ASM 34-11/01).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-11-00∞∞∞∞∞∞∞∞∞∞Page 229
 May 01/04R CES


 (b) If there is a ground signal:
 - repair the wiring from angle of attack sensor 1 (3FP1) pins A/A,M to the first terminal block (Ref. ASM 34-11/01).
 B. Do the test given in Para. 3.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-11-00∞∞∞∞∞∞∞∞∞∞Page 230
 May 01/04R
 CES  Loss of the Angle of Attack Sensor 2


 1. Possible Causes
_______________
 - SENSOR-ANGLE OF ATTACK, 2 (3FP2)

 - wiring from angle of attack sensor 2 (3FP2) pins A/B,N to the ground terminal

 - wiring from angle of attack sensor 2 (3FP2) pins A/A,M to the first terminal block


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 导航 NAVIGATION 1(12)