 May 01/04R CES


 Loss of the ADM BUS 3 Input Data to the ADIRU 2
 1. Possible Causes
_______________
 - ADM-R STATIC PRESSURE (19FP6)

 - ADIRU-2 (1FP2)

 - wiring of the ADM BUS 3 INPUT bus from the R static pressure ADM (19FP6) to the ADIRU 2 (1FP2)


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 34-11-17-000-001 Removal of the Air Data Module (19FP1,19FP2,19FP3,19FP4,19FP5,19FP6, 19FP7,19FP8) AMM 34-11-17-400-001 Installation of the Air Data Module
 (19FP1,19FP2,19FP3,19FP4,19FP5,19FP6, 19FP7,19FP8) AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3) AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3) AMM 34-13-00-740-002 INTERFACE TEST of the ADR ASM 34-13/03
 3. Fault Confirmation
__________________
 A. Test Do the Interface test of the ADR (system 2) (Ref. AMM TASK 34-13-00-740-002).
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message ADM6 (19FP6)/ADIRU2 (1FP2):
 - replace the ADM-R STATIC PRESSURE (19FP6) (Ref. AMM TASK 34-11-17-000-001) and (Ref. AMM TASK 34-11-17-400-001).
 (1) If the fault continues:
 - replace the ADIRU-2 (1FP2) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
 (a) If the fault continues:
 - do a check and repair the wiring of the ADM BUS 3 INPUT bus from the R static pressure ADM (19FP6) to the ADIRU 2 (1FP2) (Ref. ASM 34-13/03).
 B. Do the test given in Para. 3.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-11-00∞∞∞∞∞∞∞∞∞∞Page 215
 May 01/04R CES


 Loss of the ADM BUS 1 Input Data to the ADIRU 3
 1. Possible Causes
_______________
 - ADM-STBY TOTAL PRESSURE (19FP3)

 - ADIRU-3 (1FP3)

 - wiring of the ADM BUS 1 INPUT bus from the standby total pressure ADM (19FP3) to the ADIRU 3 (1FP3)


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 34-11-17-000-001 Removal of the Air Data Module (19FP1,19FP2,19FP3,19FP4,19FP5,19FP6, 19FP7,19FP8) AMM 34-11-17-400-001 Installation of the Air Data Module
 (19FP1,19FP2,19FP3,19FP4,19FP5,19FP6, 19FP7,19FP8) AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3) AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3) AMM 34-13-00-740-002 INTERFACE TEST of the ADR ASM 34-13/03
 3. Fault Confirmation
__________________
 A. Test Do the Interface test of the ADR (system 3) (Ref. AMM TASK 34-13-00-740-002).
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message ADM3 (19FP3)/ ADIRU3 (1FP3):
 - replace the ADM-STBY TOTAL PRESSURE (19FP3) (Ref. AMM TASK 34-11-17-000-001) and (Ref. AMM TASK 34-11-17-400-001).
 (1) If the fault continues:
 - replace the ADIRU-3 (1FP3) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
 (a) If the fault continues:
 - do a check and repair the wiring of the ADM BUS 1 INPUT bus from the standby total pressure ADM (19FP3) to the ADIRU 3 (1FP3) (Ref. ASM 34-13/03).
 B. Do the test given in Para. 3.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞34-11-00∞∞∞∞∞∞∞∞∞∞Page 216
 May 01/04R CES


 Loss of the ADM BUS 2 Input Data to the ADIRU 3
 1. Possible Causes
_______________
 - ADM-STBY STATIC PRESSURE (19FP8)

 - ADIRU-3 (1FP3)

 - wiring of the ADM BUS 2 INPUT bus from the standby static pressure ADM (19FP8) to the ADIRU 3 (1FP3)


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 34-11-17-000-001 Removal of the Air Data Module (19FP1,19FP2,19FP3,19FP4,19FP5,19FP6, 19FP7,19FP8) AMM 34-11-17-400-001 Installation of the Air Data Module
 (19FP1,19FP2,19FP3,19FP4,19FP5,19FP6, 19FP7,19FP8) AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3) AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3) AMM 34-13-00-740-002 INTERFACE TEST of the ADR ASM 34-13/03
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 导航 NAVIGATION 1(7)