- If the pin programming is incorrect: repair the aircraft wiring connect the electrical connector of the ADM (19FP5) install the ADIRU3.
- If the pin programming is correct: replace the ADM (19FP1) (Ref. AMM TASK 34-11-17-000-001) and (Ref. AMM TASK 34-11-17-400-001). . If the fault continues: replace the ADM (19FP4).
* If the fault continues:
replace the ADM (19FP5).
R **ON A/C 051-099, 106-149, 204-299, 301-399, 401-499,
A. If the test gives the maintenance message WRG: SDI PIN PROG/ ADIRU3 (1FP3):
- remove the ADIRU-3 (1FP3), (Ref. AMM TASK 34-12-34-000-001)
- do a check of pins AB/1A,5A,6A on the rack connector.
- compare the state of the pins with the SDI PIN PROGRAMMING given in the ASM (Ref. ASM 34-12/03).
(1) If the pin programming is incorrect:
- repair the aircraft wiring: defective pins
- install the ADIRU3 (Ref. AMM TASK 34-12-34-400-001).
(2) If the pin programming is correct:
- swap the ADIRU3 and the ADIRU1.
(a) If the fault stops:
- replace the ADIRU that you installed on side 2.
(b) If the fault continues:
- get access to the ADM-L TOTAL PRESSURE (19FP1) (Ref. AMM TASK 34-11-17-000-001) (Para. 2.B.)
- disconnect the electrical connector of the ADM (19FP1)
- make sure that there is continuity between pins A/J,K and that there is an open circuit between pins A/L,M,N,P.
1 If the pin programming is incorrect:
_
- repair the aircraft wiring (Ref. ASM 34-13/03)
- connect the electrical connector of the ADM (19FP1)
- install the ADIRU3.
2 If the pin programming is correct:
_
- get access to the ADM-R STATIC PRESSURE (19FP4) ADM-L STATIC PRESSURE (19FP5), (Ref. AMM TASK 34-11-17-000-001) (Para. 2.B.)
- disconnect the electrical connector of the ADM (19FP4)
- make sure that there is continuity between pins A/J,K,N,P and that there is an open circuit between pins A/L,M.
a If the pin programming is incorrect:
_
- repair the aircraft wiring
- connect the electrical connector of the ADM (19FP4)
- install the ADIRU3.
b If the pin programming is correct:
_
- disconnect the electrical connector of the ADM (19FP5)
- make sure that there is continuity between pins A/J,K,M,P and that there is an open circuit between pins A/L,N.
- If the pin programming is incorrect: repair the aircraft wiring connect the electrical connector of the ADM (19FP5)
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 051-099, 106-149, 204-299, 301-399, ∞∞34-13-00∞∞∞∞∞∞∞∞∞∞Page B206
401-499, Aug 01/05 CES install the ADIRU3.
- If the pin programming is correct: replace the ADM (19FP1) (Ref. AMM TASK 34-11-17-000-001) and (Ref. AMM TASK 34-11-17-400-001). . If the fault continues: replace the ADM (19FP4).
* If the fault continues: replace the ADM (19FP5).
**ON A/C ALL
B. Do the test given in Para. 3.
Loss of the CFDIU Data Input Bus on the ADIRU1
1. Possible Causes
_______________
- ADIRU-1 (1FP1)
- wiring of the CFDIU INPUT bus from the ADIRU1 (1FP1) to the first terminal bloc
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3)
AMM 34-13-00-740-002 INTERFACE TEST of the ADR
ASM 34-14/02
3. Fault Confirmation
__________________
A. Test Do the Interface test of the ADR (system 1) (Ref. AMM TASK 34-13-00-740-002).
4. Fault Isolation
_______________
A. If the BITE test gives the maintenance message CFDIU (1TW)/ADIRU1 (1FP1):
- replace the ADIRU-1 (1FP1) (Ref. AMM TASK 34-12-34-000-001) and (Ref. AMM TASK 34-12-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring of the CFDIU INPUT bus from the ADIRU1 (1FP1) to the first terminal bloc (Ref. ASM 34-14/02).
B. Do the test given in Para. 3.
Loss of the CFDIU Data Input Bus on the ADIRU2
1. Possible Causes
_______________