- remove the ADIRU-1 (1FP1) (Ref. AMM TASK 34-12-34-000-001)
- do a check of the SDI pin programming, pins AB/1A, 5A, 6A on the rack connector
- compare the state of the pins with the SDI pin programming given in the ASM (Ref. ASM 34-12/01).
(1) If the pin programming is incorrect:
- repair the SDI pin programming of the ADIRU1
- install the ADIRU1 (Ref. AMM TASK 34-12-34-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 051-099, 106-149, 204-299, 301-399, ∞∞34-13-00∞∞∞∞∞∞∞∞∞∞Page B215
401-499, Aug 01/05 CES
(2) If the pin programming is correct:
- get access to the ADM (19FP5) (Ref. AMM TASK 34-11-17-000-001) (Para. 2.B.)
- disconnect the electrical connector of the ADM (19FP5)
- make sure that there is continuity between pins A/J, K, M, P and that there is an open circuit between pins A/L, N (Ref. ASM 34-13/03).
(a) If the pin programming is incorrect:
- repair the SDI pin programming of the ADM (19FP5)
- connect the electrical connector of the ADM (19FP5)
- install the ADIRU1.
(b) If the pin programming is correct:
- install a new ADIRU1
- connect the electrical connector of the ADM (19FP5).
1 If the fault continues:
_
- replace the ADM-L STATIC PRESSURE (19FP5) (Ref. AMM TASK 34-11-17-000-001) and (Ref. AMM TASK 34-11-17-400-001).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 051-099, 106-149, 204-299, 301-399, ∞∞34-13-00∞∞∞∞∞∞∞∞∞∞Page B216
401-499, Aug 01/05 CES
Disagree between ADIRU2 and ADM7 SDI Codes
1. Possible Causes
_______________
- ADIRU-2 (1FP2)
- ADM-L STATIC PRESSURE (19FP7)
- SDI pin programming of the ADIRU2
- SDI pin programming of the ADM (19FP7)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 34-11-17-000-001 Removal of the Air Data Module (19FP1,19FP2,19FP3,19FP4,19FP5,19FP6, 19FP7,19FP8) AMM 34-11-17-400-001 Installation of the Air Data Module
(19FP1,19FP2,19FP3,19FP4,19FP5,19FP6, 19FP7,19FP8) AMM 34-12-34-000-001 Removal of the ADIRU (1FP1, 1FP2, 1FP3) AMM 34-12-34-400-001 Installation of the ADIRU (1FP1, 1FP2, 1FP3) AMM 34-13-00-740-002 INTERFACE TEST of the ADR ASM 34-12/02 ASM 34-13/03
3. Fault Confirmation
__________________
A. Test Do the Interface test of the ADR (system 2) (Ref. AMM TASK 34-13-00-740-002).
4. Fault Isolation
_______________
A. If the test gives the maintenance message WRG: SDI PIN PROG/ ADM7
(19FP7)/ ADIRU2 (1FP2):
- remove the ADIRU-2 (1FP2) (Ref. AMM TASK 34-12-34-000-001)
- do a check of the SDI pin programming, pins AB/1A, 5A, 6A on the rack connector
- compare the state of the pins with the SDI pin programming given in the ASM (Ref. ASM 34-12/02).
(1) If the pin programming is incorrect:
- repair the SDI pin programming of the ADIRU2
- install the ADIRU2 (Ref. AMM TASK 34-12-34-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 051-099, 106-149, 204-299, 301-399, ∞∞34-13-00∞∞∞∞∞∞∞∞∞∞Page B217
401-499, Aug 01/05 CES
(2) If the pin programming is correct:
- get access to the ADM (19FP7) (Ref. AMM TASK 34-11-17-000-001) (Para. 2.B.)