• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 13:49来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 WARNING : OBEY THE FUEL SAFETY PROCEDURES.
_______
 WARNING : WHEN YOU DO WORK ON THE FUEL SYSTEM WIRING, YOU MUST USE TEST
_______ EQUIPMENT THAT IS APPROVED (REFER TO INTERNATIONAL OR NATIONAL SPECIFICATIONS FOR INTRINSICALLY SAFE TEST EQUIPMENT, E.G. EN50-020, UL913 OR EQUIVALENT). TEST EQUIPMENT THAT IS NOT APPROVED CAN CAUSE FIRE OR AN EXPLOSION.
 1. Possible Causes
_______________
 - FQIC (3QT)

 - P/BSW-CTR TK/MODE SEL/AUTO (48QA)

 - aircraft wiring (FAULT ground/earth line) between the FQIC (3QT) rack connector AB, pins 8B and 9B, and the P/BSW-CTR TK/MODE SEL/AUTO (48QA), terminal C1

 - switch wiring (FAULT ground/earth line) between the P/BSW-CTR TK/MODE SEL/AUTO (48QA) terminals C3 and 8

 - aircraft wiring (AUTO/MAN line) between the P/BSW-CTR TK/MODE SEL/AUTO (48QA), terminal D2 and the SDAC-1 (1WV1) rack connector AA, pin 13G

 - aircraft wiring (AUTO/MAN line) between the P/BSW-CTR TK/MODE SEL/AUTO (48QA), terminal D2 and the SDAC-2 (1WV2) rack connector AA, pin 13G


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
28-21-00-810-813 Fuel Pumps - Center Tank Fuel Pump No. 1 (Left Side) 37QA System Malfunction 28-21-00-810-814 Fuel Pumps - Center Tank Fuel Pump No. 2 (Right Side) 38QA System Malfunction 28-21-00-810-823 Center Tank Autofeed System (Sequence/Distribution)
 Failure AMM 28-21-00-720-001 Functional Test of the Center-Tank Fuel Control AMM 28-42-34-000-001 Removal of the Fuel Quantity-Indicating Computer
 (FQIC) (3QT) AMM 28-42-34-400-001 Installation of the Fuel Quantity-Indicating Computer (FQIC) (3QT) ASM 28-21/04
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞28-21-00∞∞∞∞∞∞∞∞∞∞Page A248
 201-299, 401-499, Aug 01/05 CES

 

 3. Fault Confirmation
__________________
 A. During normal operation of the ECAM, the FUEL - AUTO FEED FAULT is a configuration warning.
 NOTE : This ECAM warning is only given in certain flight phases, and is
____
 controlled by the FWC.

 This warning function is activated simultaneously with the FAULT legend on the P/BSW-CTR TK/MODE SEL/AUTO (48QA).
 NOTE : The FAULT is only given with the P/BSW in the AUTO (in) position.
____

 These indications are given because the fuel load distribution is not correct or the fuel has not been used in the correct sequence.
 The warnings will be activated if for 60 seconds the fuel distribution (for any reason) is as follows:
 - the left wing tank, less than 5000 kg (11000 lb) AND the center tank, more than 250 kg (550 lb).

 - the right wing tank, less than 5000 kg (11000 lb) AND the center tank, more than 250 kg (550 lb).


 The warnings will be reset immediately when the fuel distribution
 conditions no longer exist.

 The source of the comparison logic which activates and resets this
 warning is contained in the FQIC (3QT).
 The FQIC warning/FAULT logic output is inhibited during automatic
 pressure refuel.

 The FQIC warning/FAULT logic output is transmitted on:

 - two (2) ARINC bus lines to the FWC (ECAM)

 - two (2) discrete signal lines OR gated together to the P/BSW-CTR TK/MODE SEL/AUTO (48QA), FAULT legend.


 (1) Examine the aircraft log/investigate the fuel configuration at the time of the original/repeat failure, and compare it with the fuel configuration given before.

 (2) Do the Functional Test of the Center-Tank Fuel Control (Ref. AMM TASK 28-21-00-720-001).

 (3) If a CTR TK PUMP 1 failure in Manual Mode is found:

 - do Center Tank Pump-Fuel No 1 System Failure (Ref. TASK 28-21-00-810-813).

 (4) If a CTR TK PUMP 2 failure in Manual Mode is found:


 - do Center Tank Pump-Fuel No 2 System Failure (Ref. TASK 28-21-00-810-814).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞28-21-00∞∞∞∞∞∞∞∞∞∞Page A249
 201-299, 401-499, Aug 01/05 CES

 

 (5) If a center tank autofeed system failure is found:

 - do the Center Tank Autofeed System (Sequence/Distribution) Failure (Ref. TASK 28-21-00-810-823).

 (6) If the FUEL - AUTO FEED FAULT ECAM warning/FAULT legend,
 