(GPCU) AMM 24-41-34-000-001 Removal of the Ground Power Control Unit (GPCU) (1XG) AMM 24-41-34-400-001 Installation of the Ground Power Control Unit (GPCU)
(1XG)
ASM 24-22/02
ASM 24-41/02
3. Fault Confirmation
__________________
A. Test Do the operational test of the GPCU (Ref. AMM TASK 24-41-00-740-002).
4. Fault Isolation
_______________
A. If the test gives the maintenance message NO DATA FROM GCU 1:
- on the circuit breaker panel 122VU, do a check of the status of the circuit breaker (2XU1).
(1) If the circuit breaker is open:
- close it.
(2) If the circuit breaker is closed:
- do a check for 28VDC on the pin A/1D of the GCU 1.
(a) If there is no 28VDC:
- do a check of the wiring between the circuit breaker (2XU1) and the GCU 1 (Ref. ASM 24-22/02).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞24-41-00∞∞∞∞∞∞∞∞∞∞Page 205
201-299, 301-399, Aug 01/05 CES (b) If there is 28VDC:
1_ If there is no continuity:
- repair the wiring.
2_ If there is continuity:
- replace the C/B-ELEC/GCU/1 (2XU1).
- do a check of the wiring of the RS422 bus between respectively the GCU 1 pins B/14C, B/14D and the GPCU pins A/13C, A/14C (Ref. ASM 24-41/02).
1 If there is no continuity:
_ - repair the above wiring.
2 If there is continuity:
_
- replace the GCU-1 (1XU1) (Ref. AMM TASK 24-22-34-000-001) and (Ref. AMM TASK 24-22-34-400-001) .
3 If the fault continues:
_
- replace the GPCU (1XG) (Ref. AMM TASK 24-41-34-000-001) and (Ref. AMM TASK 24-41-34-400-001).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞24-41-00∞∞∞∞∞∞∞∞∞∞Page 206
201-299, 301-399, Aug 01/05 CES
TASK 24-41-00-810-805
Failure of the RS422 Electrical Connection between the GPCU and the GCU 2
1. Possible Causes
_______________
- GCU-2 (1XU2)
- GPCU (1XG)
- wiring between the circuit breaker (2XU2) and the GCU 2
- C/B-ELEC/GCU 2 (2XU2)
- wiring of the RS422 bus
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 24-22-34-000-001 Removal of the GCU-1(2) (1XU1, 1XU2)
AMM 24-22-34-400-001 Installation of the GCU-1(2) (1XU1, 1XU2)
AMM 24-41-00-740-002 Operational Test of the Ground power Control Unit
(GPCU) AMM 24-41-34-000-001 Removal of the Ground Power Control Unit (GPCU) (1XG) AMM 24-41-34-400-001 Installation of the Ground Power Control Unit (GPCU)
(1XG)
ASM 24-22/02
ASM 24-41/02
3. Fault Confirmation
__________________
A. Test Do the operational test of the GPCU, (Ref. AMM TASK 24-41-00-740-002).
4. Fault Isolation
_______________
A. If the test gives the maintenance message NO DATA FROM GCU 2:
- on the circuit breaker panel 122VU, do a check of the status of the circuit breaker (2XU2).
(1) If the circuit breaker is open:
- close it.
(2) If the circuit breaker is closed:
- do a check for 28VDC on the pin A/1D of the GCU 2.
(a) If there is no 28VDC:
- do a check of the wiring between the circuit breaker (2XU2) and the GCU 2 (Ref. ASM 24-22/02).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞24-41-00∞∞∞∞∞∞∞∞∞∞Page 207
201-299, 301-399, Aug 01/05 CES (b) If there is 28VDC:
1_ If there is no continuity:
- repair the above wiring.
2_ If there is continuity:
- replace the C/B-ELEC/GCU 2 (2XU2).
- do a check of the wiring of the RS422 bus between respectively the GCU 2 pins B/14C, B/14D and the GPCU pins A/12D, A/13D (Ref. ASM 24-41/02). 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 电源 3(95)