TASK 24-30-00-810-806
Loss of the BCL2 Detected by the SDAC1
1. Possible Causes
_______________
- BAT-2 (2PB2)
- BCL-2 (1PB2)
- SDAC-1 (1WV1)
- FUSE-BAT 2 (4PB2)
- wiring from the SDAC1 (1WV1) to the BCL2 (1PB2)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 24-38-34-000-001 Removal of the Battery Charge Limiter (BCL) (1PB1, 1PB2) AMM 24-38-34-400-001 Installation of the Battery Charge Limiter (BCL)
(1PB1, 1PB2)
AMM 24-38-51-000-001 Removal of the Batteries (2PB1, 2PB2)
AMM 24-38-51-400-001 Installation of the Batteries (2PB1, 2PB2)
AMM 31-50-00-710-001 Ground Scanning of the Central Warning System
AMM 31-55-34-000-001 Removal of the SDAC (1WV1,1WV2)
AMM 31-55-34-400-001 Installation of the SDAC (1WV1,1WV2)
ASM 31-54/03
3. Fault Confirmation
__________________
A. Test Do the operational test of the central warning systems (Ref. AMM TASK 31-50-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message SDAC1 : NO DATA FROM BCL2: do a check of the battery 2 voltage.
(1) If the voltage is not correct:
- replace the BAT-2 (2PB2) (Ref. AMM TASK 24-38-51-000-001) and (Ref. AMM TASK 24-38-51-400-001).
(2) If the voltage is correct:
- replace the FUSE-BAT 2 (4PB2).
(a) If the fault continues:
- replace the BCL-2 (1PB2) (Ref. AMM TASK 24-38-34-000-001) and (Ref. AMM TASK 24-38-34-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞24-30-00∞∞∞∞∞∞∞∞∞∞Page 214
Aug 01/00R CES
(b) If the fault continues:
- replace the SDAC-1 (1WV1) (Ref. AMM TASK 31-55-34-000-001) and (Ref. AMM TASK 31-55-34-400-001).
(c) If the fault continues:
- do a check and repair the wiring from the SDAC1 (1WV1) to the BCL2 (1PB2), pins AE/11C, 11D to pins A/P, R (Ref. ASM 31-54/03).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞24-30-00∞∞∞∞∞∞∞∞∞∞Page 215
Aug 01/00R
CES TASK 24-30-00-810-807
Loss of the BCL1 Detected by the SDAC2
1. Possible Causes
_______________
- BAT-1 (2PB1)
- BCL-1 (1PB1)
- SDAC-2 (1WV2)
- FUSE-BAT 1 (4PB1)
- wiring from the SDAC2 (1WV2) to the BCL1 (1PB1)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 24-38-34-000-001 Removal of the Battery Charge Limiter (BCL) (1PB1, 1PB2) AMM 24-38-34-400-001 Installation of the Battery Charge Limiter (BCL)
(1PB1, 1PB2)
AMM 24-38-51-000-001 Removal of the Batteries (2PB1, 2PB2)
AMM 24-38-51-400-001 Installation of the Batteries (2PB1, 2PB2)
AMM 31-50-00-710-001 Ground Scanning of the Central Warning System
AMM 31-55-34-000-001 Removal of the SDAC (1WV1,1WV2)
AMM 31-55-34-400-001 Installation of the SDAC (1WV1,1WV2)
ASM 31-54/03
3. Fault Confirmation
__________________
A. Test Do the operational test of the central warning systems (Ref. AMM TASK 31-50-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message SDAC2 : NO DATA FROM BCL1: do a check of the battery 1 voltage.
(1) If the voltage is not correct:
- replace the BAT-1 (2PB1) (Ref. AMM TASK 24-38-51-000-001) and (Ref. AMM TASK 24-38-51-400-001).
(2) If the voltage is correct:
- replace the FUSE-BAT 1 (4PB1).
(a) If the fault continues:
- replace the BCL-1 (1PB1) (Ref. AMM TASK 24-38-34-000-001) and (Ref. AMM TASK 24-38-34-400-001).