(b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) (Ref. AMM TASK 31-60-00-860-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞24-60-00∞∞∞∞∞∞∞∞∞∞Page 220
Aug 01/00R
CES
B. Test
(1) Do this test:
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
On the ECAM control panel: On the upper ECAM display unit:
- push the ELEC key to get the ELEC - the ELEC DC ESS BUS SHED warning
page. comes into view.
(2) Do the operational test of the CVR channel recording (test of the CVR only) (Ref. AMM TASK 23-71-00-710-001).
4. Fault Isolation
_______________
A. Table of the circuit breakers used in this procedure:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
106VU EMER/SHED/CNTOR/SPLY 1PH C07
B. If the test confirms the fault:
- do a check of the status of the circuit breaker (1PH).
(1) If the circuit breaker (1PH) is closed:
- do a check for 28VDC between pins B/5 and B/3 of the DC SHED ESS BUS contactor (8PH) (Ref. ASM 24-62/01).
(a) If there is 28VDC on the contactor (8PH):
- replace the CNTOR-DC SHED ESS BUS (8PH) (Ref. AMM TASK 24-62-55-000-001) and (Ref. AMM TASK 24-62-55-400-001).
(b) If there is no 28VDC on the contactor (8PH):
- do a check for 28VDC at pin A/B2 of the B hydraulic pump control relay (21XE).
1 If there is 28VDC on the relay (21XE):
_ - replace the RELAY-B HYD PUMP CTL (21XE).
a If the fault continues:
_
- do a check and repair the wiring between: . pin A/B3 of the B hydraulic pump control relay (21XE) and pin B/3 of the DC SHED ESS BUS contactor (8PH), . pin B/5 of the DC SHED ESS BUS contactor (8PH) and the ground point or terminal block (Ref. ASM 24-62/01) and (Ref. AWM 24-62-02).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞24-60-00∞∞∞∞∞∞∞∞∞∞Page 221
Aug 01/00R CES
2 If there is no 28VDC on the relay (21XE):
_
- do a check for 28VDC at pin A/B2 of the static inverter control relay (6XB).
a If there is 28VDC on the relay (6XB):
_
- replace the RELAY - STAT INV CTL (6XB). . If the fault continues: do a check and repair the wiring between pin A/B3 of the static inverter control relay (6XB) and pin A/B2 of the B hydraulic pump control relay (21XE) (Ref. ASM 24-62/01).
b If there is no 28VDC on the relay (6XB):
_
- do a check and repair the wiring between the: . pin A/F of the DC ESS BUS supply contactor (4PC) and pin 1 of the EMER/SHED/ CNTOR/SPLY circuit breaker (1PH), . pin A/2 of the EMER/SHED/CNTOR/SPLY circuit breaker (1PH) and pin A/B2 of the static inverter control relay (6XB) (Ref. ASM 24-62/01) and (Ref. AWM 24-62-02).
(2) If the circuit breaker trips:
- do a check for a short to ground between the circuit breaker (1PH) and pin B/5 of the contactor (8PH) (Ref. ASM 24-62/01).
(a) If there is a short to ground:
- replace the CNTOR-DC SHED ESS BUS (8PH) (Ref. AMM TASK 24-62-55-000-001) and (Ref. AMM TASK 24-62-55-400-001).
(b) If there is no short to ground:
- replace the C/B EMER/SHED/CNTOR/SPLY (1PH).
C. Do this test to make sure that the system operates correctly:
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the ECAM control panel: On the upper ECAM display unit:
- push the ELEC key to get the - no warning comes into view. ELEC page.
On the lower ECAM display unit:
- the normal configuration comes into view.
2. On the overhead control and - on the pushbutton switch, the ON
indicating panel 21VU: legend comes on
- push the RCDR/GND CTL - make sure that you can hear the
pushbutton switch. conversations from the CVR microphone in the headset.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 电源 3(147)