TASK 24-38-00-810-828
Loss of the NOSE L/G LOCKED-UP Signal to the BCL1
1. Possible Causes
_______________
- BCL-1 (1PB1)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 24-38-00-710-001 Operational Test of the Battery Charge Limiter (BCL), (with the CFDS) AMM 24-38-34-000-001 Removal of the Battery Charge Limiter (BCL) (1PB1, 1PB2) AMM 24-38-34-400-001 Installation of the Battery Charge Limiter (BCL) (1PB1, 1PB2) ASM 24-38/01
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the BCL1 (Ref. AMM TASK 24-38-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message CHECK LGCIU1/BCL1 CIRCUIT:
- replace the BCL-1 (1PB1) (Ref. AMM TASK 24-38-34-000-001) and (Ref. AMM TASK 24-38-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring from the pin A/s of the BCL1 to the first terminal block (Ref. ASM 24-38/01).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞24-38-00∞∞∞∞∞∞∞∞∞∞Page 235
May 01/00R
CES
TASK 24-38-00-810-829
Loss of the NOSE L/G LOCKED-UP Signal to the BCL2
1. Possible Causes
_______________
- BCL-2 (1PB2)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 24-38-00-710-001 Operational Test of the Battery Charge Limiter (BCL), (with the CFDS) AMM 24-38-34-000-001 Removal of the Battery Charge Limiter (BCL) (1PB1, 1PB2) AMM 24-38-34-400-001 Installation of the Battery Charge Limiter (BCL) (1PB1, 1PB2) ASM 24-38/02
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the BCL2 (Ref. AMM TASK 24-38-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message CHECK LGCIU1/BCL2 CIRCUIT
- replace the BCL-2 (1PB2) (Ref. AMM TASK 24-38-34-000-001) and (Ref. AMM TASK 24-38-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring from the pin A/s of the BCL2 to the first terminal block (Ref. ASM 24-38/02).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞24-38-00∞∞∞∞∞∞∞∞∞∞Page 236
May 01/00R
CES TASK 24-38-00-810-830
Loss of the EMERGENCY CONFIGURATION Signal to the BCL1
1. Possible Causes
_______________
- BCL-1 (1PB1)
- wiring
- RELAY-BUS 1XP CTL (15XC)
- RELAY-BUS 2XP CTL (16XC)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 24-38-00-710-001 Operational Test of the Battery Charge Limiter (BCL), (with the CFDS) AMM 24-38-34-000-001 Removal of the Battery Charge Limiter (BCL) (1PB1, 1PB2) AMM 24-38-34-400-001 Installation of the Battery Charge Limiter (BCL) (1PB1, 1PB2) ASM 24-38/01
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the BCL1 (Ref. AMM TASK 24-38-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message RELAYS 15XC or 16XC/BCL1 CIRCUIT
- replace the BCL-1 (1PB1) (Ref. AMM TASK 24-38-34-000-001) and (Ref. AMM TASK 24-38-34-400-001).
(1) If the fault continues:
- do a check of the wiring from the pin A/Y of the BCL1 to the pin A/A3 of the relay (15XC) and from the pin A/A2 of this relay to the pin A/A3 of the relay (16XC) (Ref. ASM 24-38/01).
(a) If there is no continuity:
- repair the wiring.
(b) If there is continuity:
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 电源 3(63)