 - RELAY-GND/FLT SELECT CTL (7XX)

 - CNTOR-AC & DC GND SVCE SPLY (14XX)

 - wiring

 - C/B-TR2 SPLY (2PU2)


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 24-32-55-000-001 Removal of the Transformer 1(2) Contactor (5PU1, 5PU2, 14PU) AMM 24-32-55-400-001 Installation of the Transformer 1(2) Contactor (5PU1, 5PU2, 14PU) AMM 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power AMM 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
 from the External Power AMM 31-60-00-860-001 EIS Start Procedure ASM 24-32/01 ASM 24-42/01
 3. Fault Confirmation
__________________
 A. Job Set-up
 (1) Aircraft Maintenance Configuration
 (a) Energize the aircraft electrical circuits
 (Ref. AMM TASK 24-41-00-861-002).


 (b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) (Ref. AMM TASK 31-60-00-860-001).


 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞24-60-00∞∞∞∞∞∞∞∞∞∞Page 214
 Aug 01/00R
 CES


 B. Test
 Do this test:

 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the ECAM control panel: On the upper ECAM display unit:
 - push the ELEC key to get the  - the ELEC TR2 FAULT warning comes into ELEC page. view.
 2. On the FWD attendant panel 120RH: In the cabin:
 - push the CABIN WDO and CABIN  - the ceiling FWD and AFT lights (right
 CLG pushbutton switches.  hand) and the window FWD and AFT lights (left hand) remain off.
 4. Fault Isolation
_______________
 A. Table of the circuit breakers used in this procedure:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------122VU ELEC/AC PWR/SVCE/CTL 3XX V29 123VU TR2/214XP/SPLY 2PU2 AB04
R **ON A/C 001-049, 051-062, 101-105, 151-152, 201-205,
 B. If the test confirms the fault:
 - do a check of the status of the circuit breaker (2PU2).
 (1) If this circuit breaker is closed:
 - replace the CNTOR-TR 2/AC SVCE BUS NORM SPLY (14PU) (Ref. AMM TASK 24-32-55-000-001) and (Ref. AMM TASK 24-32-55-400-001).
 (a) If the fault continues:

 - replace the RELAY-GND/FLT SELECT CTL (7XX).

 (b) If the fault continues:

 - replace the CNTOR-AC & DC GND SVCE SPLY (14XX).

 (c) If the fault continues:


 - do a check and repair the wiring between respectively: . the circuit breaker (3XX) and the pin B/3 of the TR2/AC SVCE BUS normal supply contactor (14PU) . the pin B/5 of the contactor (14PU) and the ground (Ref. ASM 24-32/01) and (Ref. ASM 24-42/01).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞24-60-00∞∞∞∞∞∞∞∞∞∞Page 215
 May 01/05 CES (2) If the circuit breaker is open:


 - close it.
 (a) If it trips:
 - do a check of the wiring for a short to ground between respectively the pins A/2, B/2, C/2 of the circuit breaker (2PU2) and the pins A/D, A/E, A/F of the TR2/AC SVCE BUS normal supply contactor (14PU) (Ref. ASM 24-32/01).
 1 If the wiring is not correct:
_ - repair it.
 2 If the wiring is correct:
_ - replace the C/B-TR2 SPLY (2PU2).
R **ON A/C 063-099, 106-149, 153-199, 206-299, 301-399, 401-499,
 B. If the test confirms the fault:
 - do a check of the status of the circuit breaker (2PU2).
 (1) If this circuit breaker is closed:

 - replace the CNTOR-TR 2/AC SVCE BUS NORM SPLY (14PU) (Ref. AMM TASK 24-32-55-000-001) and (Ref. AMM TASK 24-32-55-400-001).
 (a) If the fault continues:

 - replace the RELAY-GND/FLT SELECT CTL (7XX).

 (b) If the fault continues:

 - replace the CNTOR-AC & DC GND SVCE SPLY (14XX).

 (c) If the fault continues:


 - do a check and repair the wiring between respectively: . the circuit breaker (3XX) and the pin B/3 of the TR2/AC SVCE BUS normal supply contactor (14PU) . the pin B/5 of the contactor (14PU) and the ground (Ref. ASM 24-32/01) and (Ref. ASM 24-42/01).
 