- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 24-38-00-710-001 Operational Test of the Battery Charge Limiter (BCL), (with the CFDS) AMM 24-38-34-000-001 Removal of the Battery Charge Limiter (BCL) (1PB1, 1PB2) AMM 24-38-34-400-001 Installation of the Battery Charge Limiter (BCL) (1PB1, 1PB2) ASM 24-24/02
3. Fault Confirmation
__________________
A. Test Do the Operational Test of the BCL (Ref. AMM TASK 24-38-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message RELAY 31XE/BCL1 CIRCUIT:
NOTE : This CFDS message can be found with the subsequent CFDS message:
____ RELAY 31XE/BCL2 CIRCUIT. In this case, refer to the related trouble shooting. If not, do the trouble shooting given below.
- do a check of the wiring from the pin A/t of the BCL1 to the first branch point (Ref. ASM 24-24/02).
(1) If the fault continues:
- replace the BCL-1 (1PB1) (Ref. AMM TASK 24-38-34-000-001) and (Ref. AMM TASK 24-38-34-400-001).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞24-24-00∞∞∞∞∞∞∞∞∞∞Page 201
Feb 01/98 CES
TASK 24-24-00-810-802
Failure of the RAT/EMER GEN/FAULT Indication Circuit (Linked to the BCL2)
1. Possible Causes
_______________
- BCL-2 (1PB2)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 24-38-00-710-001 Operational Test of the Battery Charge Limiter (BCL), (with the CFDS) AMM 24-38-34-000-001 Removal of the Battery Charge Limiter (BCL) (1PB1, 1PB2) AMM 24-38-34-400-001 Installation of the Battery Charge Limiter (BCL) (1PB1, 1PB2) ASM 24-24/02
3. Fault Confirmation
__________________
A. Test Do the Operational Test of the BCL2 (Ref. AMM TASK 24-38-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message RELAY 31XE/BCL2 CIRCUIT:
NOTE : This CFDS message can be found with the subsequent CFDS message:
____ RELAY 31XE/BCL1 CIRCUIT. In this case, refer to the related trouble shooting. If not, do the trouble shooting given below.
- do a check of the wiring from the pin A/t of the BCL2 to the first branch point (Ref. ASM 24-24/02).
(1) If the fault continues:
- replace the BCL-2 (1PB2) (Ref. AMM TASK 24-38-34-000-001) and (Ref. AMM TASK 24-38-34-400-001).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞24-24-00∞∞∞∞∞∞∞∞∞∞Page 202
Feb 01/98 CES
TASK 24-24-00-810-803
Failure of the RAT/EMER GEN/FAULT Indication Circuit
1. Possible Causes
_______________
- wiring
- RELAY-ANN 14XE SPLY (31XE)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 24-38-00-710-001 Operational Test of the Battery Charge Limiter (BCL),
(with the CFDS)
ASM 24-24/02
ASM 24-62/01
3. Fault Confirmation
__________________
A. Test Do the Operational Test of the BCL (Ref. AMM TASK 24-38-00-710-001).
4. Fault Isolation
_______________
A. If the tests give the maintenance messages RELAY 31XE/BCL1 CIRCUIT, and RELAY 31XE/BCL2 CIRCUIT:
- do a check of the wiring: . from the circuit breaker (1PH) to the pin A/Z of the relay (31XE), and . from the pin A/Z of the relay (31XE) to the first branch point (Ref. ASM 24-62/01) and (Ref. ASM 24-24/02).
(1) If the wiring is not correct:
- repair it.
(2) If the wiring is correct:
- replace the RELAY-ANN 14XE SPLY (31XE).
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 电源 3(26)