TASK 24-38-00-810-821
Internal Passive Failure of the BCL2
1. Possible Causes
_______________
- BCL-2 (1PB2)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 24-38-00-710-001 Operational Test of the Battery Charge Limiter (BCL), (with the CFDS) AMM 24-38-34-000-001 Removal of the Battery Charge Limiter (BCL) (1PB1, 1PB2) AMM 24-38-34-400-001 Installation of the Battery Charge Limiter (BCL) (1PB1, 1PB2)
3. Fault Confirmation
__________________
A. Test Do the operational test of the BCL (Ref. AMM TASK 24-38-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message BCL2:
- replace the BCL-2 (1PB2) (Ref. AMM TASK 24-38-34-000-001) and (Ref. AMM TASK 24-38-34-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞24-38-00∞∞∞∞∞∞∞∞∞∞Page 224
May 01/00R
CES
TASK 24-38-00-810-822
Failure of the Electrical Wiring between the BCL1 and the ADIRU1 or the LGCIU
1. Possible Causes
_______________
- BCL-1 (1PB1)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 24-38-00-710-001 Operational Test of the Battery Charge Limiter (BCL), (with the CFDS) AMM 24-38-34-000-001 Removal of the Battery Charge Limiter (BCL) (1PB1, 1PB2) AMM 24-38-34-400-001 Installation of the Battery Charge Limiter (BCL)
(1PB1, 1PB2)
ASM 24-24/02
ASM 24-38/01
3. Fault Confirmation
__________________
A. Test Do the operational test of the BCL1 (Ref. AMM TASK 24-38-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message BCL1 : LGCIU/ADIRU1 SIGNAL DISAGREE:
NOTE : This CFDS message can be found with these CFDS messages:
____ . LGCIU1 or . ADIRU1 and BCL2 : LGCIU/ADIRU1 SIGNAL DISAGREE. In this case, refer to the related trouble shooting. If not do the trouble shooting given below:
- do a check of the wiring for open circuit or short to ground: . from the pin A/g of the BCL1 to the first branch point . between the pin A/K of the BCL1 and the pin B/2D of the LGCIU1 (Ref. ASM 24-24/02) and (Ref. ASM 24-38/01).
(1) If the wiring is not correct:
- repair it.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞24-38-00∞∞∞∞∞∞∞∞∞∞Page 225
May 01/00R CES
(2) If the wiring is correct:
- replace the BCL-1 (1PB1) (Ref. AMM TASK 24-38-34-000-001) and (Ref. AMM TASK 24-38-34-400-001).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞24-38-00∞∞∞∞∞∞∞∞∞∞Page 226
May 01/00R
CES TASK 24-38-00-810-823
Failure of the Electrical Wiring between the BCL2 and the ADIRU1 or the LGCIU
1. Possible Causes
_______________
- BCL-2 (1PB2)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 24-38-00-710-001 Operational Test of the Battery Charge Limiter (BCL), (with the CFDS) AMM 24-38-34-000-001 Removal of the Battery Charge Limiter (BCL) (1PB1, 1PB2) AMM 24-38-34-400-001 Installation of the Battery Charge Limiter (BCL)
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 电源 3(60)