REFUELING ON BATTERY - FAULT ISOLATION PROCEDURES
_________________________________________________
TASK 24-67-00-810-801
Refueling not Possible
1. Possible Causes
_______________
- CNTOR-DC SVCE BUS GND SPLY (3PX)
- CNTOR-DC SVCE BUS NORM SPLY (8PN)
- RELAY - REFLNG NORM/BAT (5PR)
- RELAY - REFLNG BUS 501PP CTL (8PR)
- CTL PNL - REFUEL/DEFUEL (800VU)
- wiring
- C/B - REFLNG/501PP/BAT (1PR)
- C/B - ELEC/RFL/SPLY/LOGIC (4PR)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power AMM 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power AMM 24-43-55-000-001 Removal of the DC Service Bus Ground Supply Contactor (3PX) AMM 24-43-55-400-001 Installation of the DC Service Bus Ground Supply Contactor (3PX) AMM 24-61-55-000-001 Removal of the DC Service Bus Normal Supply Contactor (8PN) AMM 24-61-55-400-001 Installation of the DC Service Bus Normal Supply
Contactor (8PN)
AMM 28-25-55-000-001 Removal of the Refuel Panel 800VU
AMM 28-25-55-400-001 Installation of the Refuel Panel 800VU
ASM 24-67/01
3. Fault Confirmation
__________________
A. Job Set-up
(1) Aircraft Maintenance Configuration
(a) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
B. Test
No applicable, the fault is evident.
4. Fault Isolation
_______________
A. Table of the circuit breakers used in this procedure:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------122VU ELEC/RFL/SPLY/LOGIC 4PR U29 122VU ELEC/REFLNG/ON/BAT 1PR U28
B. If the refueling is not possible:
- do a check of the battery 1 voltage.
(1) If the voltage is correct:
- do a check of the status of the circuit breakers (1PR) and (4PR).
(a) If the circuit breakers are closed:
- replace the RELAY - REFLNG NORM/BAT (5PR) and RELAY - REFLNG BUS 501PP CTL (8PR).
1 If the fault continues:
_
- replace the CNTOR-DC SVCE BUS GND SPLY (3PX) (Ref. AMM TASK 24-43-55-000-001) and (Ref. AMM TASK 24-43-55-400-001).
2 If the fault continues:
_
- replace the CNTOR-DC SVCE BUS NORM SPLY (8PN) (Ref. AMM TASK 24-61-55-000-001) and (Ref. AMM TASK 24-61-55-400-001).
3 If the fault continues:
_
- replace the CTL PNL - REFUEL/DEFUEL (800VU) (Ref. AMM TASK 28-25-55-000-001) and (Ref. AMM TASK 28-25-55-400-001).
4 If the fault continues:
_
- do a check and repair the wiring between respectively: . the circuit breaker (1PR) and the pin A/C1 of the relay (5PR) . the circuit breaker (4PR) and the pins A/X1 and A/A1 of the relay (5PR) . the pin A/X2 of the relay (5PR) and the ground, through the contactors (3PX and 8PN), the switch (10PR) or the relay (11PR), and the microswitch (20QU) . the pin A/C2 of the relay (5PR) and the pins A/A1, A/C1 and A/X1 of the relay (8PR) . the pin A/A2 of the relay (8PR) and the terminal block . the pin A/C2 of the relay (8PR) and the terminal block . the pin A/X2 of the relay (8PR) and the ground (Ref. ASM 24-67/01).
(b) If the circuit breaker (1PR) is open:
- close the circuit breaker.
1_ If the circuit breaker (1PR) trips:
- do a check of the wiring for a short to ground between:
. the circuit breaker and the pins A/A1, A/C1 and A/X1 of
the relay (8PR)
. the pin A/A2 of the relay (8PR) and the terminal block
. the pin A/C2 of the relay (8PR) and the terminal block
(Ref. ASM 24-67/01).
a If the wiring is not correct:
_
- repair it. b If the wiring is correct:
_ - replace the C/B - REFLNG/501PP/BAT (1PR).
(c) If the circuit breaker (4PR) is open:
- close the circuit breaker. 1 If the circuit breaker (4PR) trips:
_
- do a check of the wiring between the circuit breaker and the pin A/X1 of the relay (5PR) (Ref. ASM 24-67/01).
a If the wiring is not correct:
_
- repair it. b If the wiring is correct:
_ - replace the C/B - ELEC/RFL/SPLY/LOGIC (4PR).