_ - repair or replace as necessary.
 b If the wiring is correct:
_
 - replace the GAPCU (24XG) (Ref. AMM TASK 24-41-34-000-001) and (Ref. AMM TASK 24-41-34-400-001).
 B. Test
 (1) Energize the aircraft electrical circuits from the external power (Ref. AMM TASK 24-41-00-861-002).

 (2) De-energize the aircraft electrical circuits from the external power (Ref. AMM TASK 24-41-00-862-002).

 

 TASK 24-41-00-810-828


 Failure of the External Power or the Phase A of the POR Sense Wiring
 1. Possible Causes
_______________
 - GAPCU (24XG)

 - external power

 - wiring

 - feeders


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power AMM 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power AMM 24-41-34-000-001 Removal of the Ground Auxiliary Power Control Unit (GAPCU) (24XG) AMM 24-41-34-400-001 Installation of the Ground Auxiliary Power Control Unit (GAPCU) (24XG) ASM 24-41/01
 3. Fault Confirmation
__________________
 A. Test
 (1) Energize the aircraft electrical circuits from the external power (Ref. AMM TASK 24-41-00-861-002).
 4. Fault Isolation
_______________
 A. Table of the circuit breakers used in this procedure:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
123VU GND/PWR/PROT 2XG AB07 B. If the external power does not energize the aircraft electrical circuits:


 - repair or replace the external power.
 (1) If the fault continues:
 - do a check of the status of the GND/PWR/PROT circuit breaker (2XG).
 (a) If the circuit breaker is open:

 - close it.

 (b) If the circuit breaker is closed:


 1_ If the circuit breaker trips:
 - do a check and repair the Point-Of-Regulation (POR) sense
 wiring of the external power (Ref. ASM 24-41/01) for a short
 to ground or a short circuit between pin A2 of the
 GND/PWR/PROT circuit breaker (2XG) and pin B/15J of the
 GAPCU.

 - do a check of the Point-Of-Regulation (POR) sense wiring (Ref. ASM 24-41/01) for an open circuit or a short circuit between pin A/J of the EPC (3XG) and pin B/15J of the GAPCU.
 1 If the wiring is not correct:
_ - repair or replace as necessary.
 2 If the wiring is correct:
_
 - do a check of the external power feeders (Ref. ASM 24-41/01) for an open circuit, a short circuit or a short to airframe between pin A of the external power receptacle (20XG) and pin A/K of the EPC (3XG).
 a If the feeders are not correct:
_
 - repair or replace as necessary.
 b If the feeders are correct:
_
 - replace the GAPCU (24XG) (Ref. AMM TASK 24-41-34-000-001) and (Ref. AMM TASK 24-41-34-400-001).
 C. Test
 (1) Energize the aircraft electrical circuits from the external power (Ref. AMM TASK 24-41-00-861-002).

 (2) De-energize the aircraft electrical circuits from the external power (Ref. AMM TASK 24-41-00-862-002).

 

 TASK 24-41-00-810-829


 Failure of the External Power Interlock-Wiring
 1. Possible Causes
_______________
 - GAPCU (24XG)

 - external power

 - external power plug

 - wiring


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
AMM 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power AMM 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power AMM 24-41-34-000-001 Removal of the Ground Auxiliary Power Control Unit (GAPCU) (24XG) AMM 24-41-34-400-001 Installation of the Ground Auxiliary Power Control Unit (GAPCU) (24XG) ASM 24-41/01
 3. Fault Confirmation
__________________
 A. Test
 (1) Energize the aircraft electrical circuits from the external power (Ref. AMM TASK 24-41-00-861-002).
 4. Fault Isolation
_______________
 A. If the test confirms the fault:
 
中国航空网 www.aero.cn