(b) If the fault continues:
- replace the SDAC-2 (1WV2) (Ref. AMM TASK 31-55-34-000-001) and (Ref. AMM TASK 31-55-34-400-001).
(c) If the fault continues:
- do a check and repair the wiring from the SDAC2 (1WV2) to the BCL1 (1PB1), pins AB/11G, 11H to pins A/d, e (Ref. ASM 31-54/03).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞24-30-00∞∞∞∞∞∞∞∞∞∞Page 217
Aug 01/00R
CES
TASK 24-30-00-810-808
Loss of the BCL2 Detected by the SDAC2
1. Possible Causes
_______________
- BAT-2 (2PB2)
- BCL-2 (1PB2)
- SDAC-2 (1WV2)
- FUSE-BAT 2 (4PB2)
- wiring from the SDAC2 (1WV2) to the BCL2 (1PB2)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 24-38-34-000-001 Removal of the Battery Charge Limiter (BCL) (1PB1, 1PB2) AMM 24-38-34-400-001 Installation of the Battery Charge Limiter (BCL)
(1PB1, 1PB2)
AMM 24-38-51-000-001 Removal of the Batteries (2PB1, 2PB2)
AMM 24-38-51-400-001 Installation of the Batteries (2PB1, 2PB2)
AMM 31-50-00-710-001 Ground Scanning of the Central Warning System
AMM 31-55-34-000-001 Removal of the SDAC (1WV1,1WV2)
AMM 31-55-34-400-001 Installation of the SDAC (1WV1,1WV2)
ASM 31-54/03
3. Fault Confirmation
__________________
A. Test Do the operational test of the central warning systems (Ref. AMM TASK 31-50-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message SDAC2 : NO DATA FROM BCL2: do a check of the battery 2 voltage.
(1) If the voltage is not correct:
- replace the BAT-2 (2PB2) (Ref. AMM TASK 24-38-51-000-001) and (Ref. AMM TASK 24-38-51-400-001).
(2) If the voltage is correct:
- replace the FUSE-BAT 2 (4PB2).
(a) If the fault continues:
- replace the BCL-2 (1PB2) (Ref. AMM TASK 24-38-34-000-001) and (Ref. AMM TASK 24-38-34-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞24-30-00∞∞∞∞∞∞∞∞∞∞Page 218
Aug 01/00R CES
(b) If the fault continues:
- replace the SDAC-2 (1WV2) (Ref. AMM TASK 31-55-34-000-001) and (Ref. AMM TASK 31-55-34-400-001).
(c) If the fault continues:
- do a check and repair the wiring from the SDAC2 (1WV2) to the BCL2 (1PB2), pins AE/11C, 11D to pins A/d, e (Ref. ASM 31-54/03).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞24-30-00∞∞∞∞∞∞∞∞∞∞Page 219
Aug 01/00R
CES
TASK 24-30-00-810-809
Failure of one TR found by the CFDIU
1. Possible Causes
_______________
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R AMM 31-32-00-740-002 BITE Test of the Centralized Fault Display Interface
R Unit (CFDIU) ASM 24-34/01 ASM 24-35/02 ASM 31-32/06
3. Fault Confirmation
__________________
A. Test Do the BITE test of the CFDIU (Ref. AMM TASK 31-32-00-740-002).
4. Fault Isolation
_______________
A. If the test gives the message TR:
- do a check for other CFDS messages or warnings related to the DC main generator system (TR) on the upper ECAM display unit.
(1) If there are other messages or warnings:
- do the trouble shooting related to these messages or warnings.
(2) If there is no message and no warning:
- do a check and repair the wiring between: . the pin A/A1 of the relay (8PC1) and the pin AA/1J of the CFDIU (1TW) . the pin A/A1 of the relay (8PC2) and the pin AB/5A of the CFDIU (Ref. ASM 24-35/02) and (Ref. ASM 31-32/06) . the pin B/E of the ESS TR (1PE) and the pin AA/7K of the CFDIU (Ref. ASM 24-34/01) and (Ref. ASM 31-32/06).
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 电源 3(42)