• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 13:22来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

R  shooting procedure.


R TASK 24-22-00-810-826


R Failure of the GLC 2 Status Indication R 1. Possible Causes
_______________
R - GCU-2 (1XU2) R - GLC-2 (9XU2) R - wiring
R 2. Job Set-up Information
______________________
R A. Referenced Information
R -------------------------------------------------------------------------------R REFERENCE DESIGNATION R -------------------------------------------------------------------------------
R AMM 24-22-34-000-001 R AMM 24-22-34-400-001 R AMM 24-22-55-000-001 R AMM 24-22-55-400-002 R R AMM 24-41-00-740-002 R ASM 24-22/03
R 3. Fault Confirmation
__________________
R A. Test
Removal of the GCU-1(2) (1XU1, 1XU2)
Installation of the GCU-1(2) (1XU1, 1XU2)
Removal of the Contactors (9XU1, 9XU2, 11XU1, 11XU2)
Installation of the Contactors (9XU1, 9XU2, 11XU1,
11XU2)
Operational Check of GAPCU via CFDS

R (1) Do the BITE test of the GAPCU (Ref. AMM TASK 24-41-00-740-002).

R (a) If the BITE test gives the message TEST FAILED:
R - do the trouble shooting given in Para 4.A.
R (b) If the BITE test gives the message TEST PASSED:

R - do the trouble shooting given in Para 4.B. R 4. Fault Isolation
_______________
R A. If the BITE test gives the message TEST FAILED:
R - push the line key adjacent to the TEST FAILED message.

R (1) If the maintenance message GCU2 (1XU2) comes into view:
R - replace the GCU-2 (1XU2) (Ref. AMM TASK 24-22-34-000-001) and (Ref.
R AMM TASK 24-22-34-400-001).

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 401-499, ∞∞24-22-00∞∞∞∞∞∞∞∞∞∞Page 271
 Aug 01/05 CES


R  B. If the BITE test gives the message TEST PASSED: 
R  - do a check of the contact for correct operation of the GLC 2 (9XU2) 
R  between pins B/18 and B/20 (Ref. ASM 24-22/03). 
R  (1) If the contact does not operate correctly: 
R  - replace the GLC-2 (9XU2) (Ref. AMM TASK 24-22-55-000-001) and (Ref. 
R  AMM TASK 24-22-55-400-002) as necessary. 
R  (2) If the contact operates correctly: 
R  - do a check of the wiring of the GLC 2 sence circuit (Ref. ASM 24-
R  22/03) for an open circuit between: 
R  . pin 2 of the ELEC/GCU2 circuit breaker (2XU2) and pin B/18 of the 
R  GLC 2 (9XU1) 
R  . pin B/20 of the GLC 2 and pin A/30 of the diode module 2420VD 
R  . pin A/15 of the diode module 2420VD and pin A/6A of the GCU 2. 
R  (a) If the wiring is not correct: 
R  - repair or replace as necessary. 
R  (b) If the wiring is correct: 
R  - replace the GCU-2 (1XU2) (Ref. AMM TASK 24-22-34-000-001) and 
R  (Ref. AMM TASK 24-22-34-400-001). 
R  C. When you replace a component or repair the wiring: 
R  - do the subsequent flight before you do the check of the Class 3 Faults 
R  of the GAPCU from the CFDS to make sure that the system operates 
R  correctly. 
R  If the test continues to give the fault message, continue the trouble 
R  shooting procedure.


R TASK 24-22-00-810-827


R Failure of the ELEC/GEN 1 Pushbutton Switch R 1. Possible Causes
_______________
R - P/BSW-ELEC/GEN 1 (3XU1)
R - GCU-1 (1XU1)
R - wiring

R 2. Job Set-up Information

______________________
R A. Referenced Information
R -------------------------------------------------------------------------------R REFERENCE DESIGNATION R -------------------------------------------------------------------------------
R  AMM  24-22-34-000-001  Removal of the GCU-1(2) (1XU1, 1XU2) 
R  AMM  24-22-34-400-001  Installation of the GCU-1(2) (1XU1, 1XU2) 
R  AMM  24-41-00-740-002  Operational Check of GAPCU via CFDS 
R  ASM  24-22/02 
R  3. Fault Confirmation__________________ 
R  A. Test 

R (1) Do the BITE test of the GAPCU (Ref. AMM TASK 24-41-00-740-002).
R 4. Fault Isolation
_______________
R A. Table of the circuit breakers used in this procedure:
R -------------------------------------------------------------------------------R PANEL DESIGNATION IDENT. LOCATION R -------------------------------------------------------------------------------R 122VU ELEC/GCU/1 2XU1 T26
R B. If the BITE test gives the maintenance message PB SW ELEC GEN1 (3XU1)/ R GCU1 (1XU1):
R NOTE : After you do the trouble shooting for this fault, open and close
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 电源 3(3)