(1) Make sure that the work area is clean and clear of tool(s) and other items.
(2) Close the fan cowl doors: (Ref. TASK 71-13-00-410-040)
FOR 1000EM1
437AL, 438AR
FOR 1000EM2
447AL, 448AR
(3) Remove the access platform(s).
(4) Remove the warning notice(s). Subtask 78-31-49-710-071
C. Bleed the air from the thrust reverser hydraulic system. (Ref. TASK 78-30-00-710-040)
F 『 EEFF : ALL E Page 44978-31-49
E E Feb 01/98 E E ECES E
F 『
E C F M E
E E
E 56-5B E
E E
TASK 78-31-49-000-046
Removal of the Return Pipe of the Right Latch
WARNING : WEAR A FACE SHIELD WHICH IS RESISTANT TO HIGH PRESSURE JETS WHEN YOU
_______
WORK ON PRESSURIZED SYSTEMS.
R WARNING : DO NOT GET THE FLUID ON YOUR SKIN OR IN YOUR EYES. IF YOU DO:
_______ R - FLUSH IT AWAY WITH CLEAN WATER R - GET MEDICAL AID.
CAUTION : USE 2 WRENCHES TO REMOVE OR INSTALL THE TUBE COUPLING NUTS.
_______
ONE WRENCH TO HOLD THE UNION AND ONE TO LOOSEN OR TIGHTEN THE
COUPLING NUT. THIS WILL PREVENT DAMAGE TO THE HARDWARE.
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific container 1 USgal (4 L)
No specific protective covers
No specific warning notice
No specific access platform 1 m (3 ft. 3 in.)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
71-13-00-010-040 Opening of the Fan Cowl Doors
78-30-00-481-041 Make the Thrust Reverser Unserviceable for
Maintenance
78-31-49-991-307 Fig. 406
F 『 EEFF : ALL E Page 45078-31-49
E E May 01/05 E E ECES E E 56-5B E
F 『
E C F M E
E E
E E
3. Job Set-up
__________ Subtask 78-31-49-941-081
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a warning notice to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a warning notice to tell persons not to energize the FADEC 1(2).
Subtask 78-31-49-010-115
B. Get Access
(1) Open the fan cowl doors: (Ref. TASK 71-13-00-010-040)
FOR 1000EM1
437AL, 438AR
FOR 1000EM2
447AL, 448AR
(2) Put the access platform in position. Subtask 78-31-49-040-107
C. Make the thrust reverser unserviceable (Ref. TASK 78-30-00-481-041).
F 『 EEFF : ALL E Page 45178-31-49
E E Feb 01/98 E E ECES E
F 『
E C F M E
E E
E 56-5B E
E E
4. Procedure
_________ (Ref. Fig. 406/TASK 78-31-49-991-307) Subtask 78-31-49-020-079
A. Removal of the Return Pipe of the Right Latch
(1) Put a container 1 USgal (4 L) under the upper latch of the blocker door.
(2) Disconnect the return pipe from the upper latch and let the hydraulic fluid drain into the container.
(3) Remove the nuts and the bolts that attach the flange and the upper half clamp to the upper hydraulic line bracket.
(4) Disconnect the interface hydraulic hose from the return pipe.
(5) Remove the nut that attach the return pipe to the interface bracket.
(6) Remove the return pipe from the forward frame.
(7) Put protective covers on the pipe ends.
F 『 EEFF : ALL E Page 45278-31-49
E E Feb 01/98 E E ECES E F 『 E C F M E E E E 56-5B E