REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
71-13-00-010-040 Opening of the Fan Cowl Doors
 71-13-00-410-040 Closing of the Fan Cowl Doors
 78-30-00-081-041 Make the Thrust Reverser Serviceable after

 Maintenance
 78-30-00-481-041 Make the Thrust Reverser Unserviceable for
 Maintenance
 78-31-18-000-001 Removal of the Blocker Door Stow-switch
 (4104KS1,4104KS2,4104KS3,4104KS4)
 78-31-18-400-001 Installation of the Blocker Door Stow-switch
 (4104KS1,4104KS2,4104KS3,4104KS4)
 78-32-41-080-001 Removal of the Safety Sleeve from Blocker Door
 Actuator
 78-32-41-480-001 Installation of the Safety Sleeve on Blocker Door

 Actuator
 78-32-41-860-001 Manual Deployment of the Blocker Door
 78-32-41-860-002 Manual Stowing of the Blocker Door
 78-36-00-010-040 Opening of the Thrust Reverser Doors

 F 『 EEFF : ALL E Page 60178-31-18
 E E Feb 01/98 E E ECES E -------------------------------------------------------------------------------

 F  『
 E  C F M  E
 E  E
 E  56-5B  E
 E  E


REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
78-36-00-410-040 Closing of the Thrust Reverser Doors
 78-31-18-991-301 Fig. 601
 3. Job Set-up
__________
 Subtask 78-31-18-941-051

 A. Safety Precautions
 (1) On the center pedestal, on the ENG panel 115VU:

 (a) Put a warning notice to tell persons not to start the engine.

 (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.

 (3) On the overhead maintenance panel 50VU:

 (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.

 (b) Put a warning notice to tell persons not to energize the FADEC 1(2).

 


 Subtask 78-31-18-010-051
 B. Get Access
 (1) Open the fan cowl doors: (Ref. TASK 71-13-00-010-040)
 FOR 1000EM1
 437AL, 438AR
 FOR 1000EM2
 447AL, 448AR

 (2) Put the access platform in position.
 Subtask 78-31-18-040-051


 C. Make the thrust reverser unserviceable (Ref. TASK 78-30-00-481-041).
 Subtask 78-31-18-860-052

 

 D. Deploy the blocker door manually (Ref. TASK 78-32-41-860-001).
 F 『 EEFF : ALL E Page 60278-31-18
 E E Feb 01/98 E E ECES E Subtask 78-31-18-481-050

 F  『
 E  C F M  E
 E  E
 E  56-5B  E
 E  E


 E. Install the SAFETY SLEEVE - PIVOTING DOOR ACTUATOR (HIX3005) on blocker door actuator (Ref. TASK 78-32-41-480-001).
 Subtask 78-31-18-010-052
 F. Open the thrust reverser doors: (Ref. TASK 78-36-00-010-040)
 FOR 1000EM1
 451AL, 452AR
 FOR 1000EM2
 461AL, 462AR

 4. Procedure
_________
 (Ref. Fig. 601/TASK 78-31-18-991-301)
 Subtask 78-31-18-210-050
 A. Do a visual inspection of the stow switch and the related hardware, the lever of the stow switch and the electrical connector as follows :
 -------------------------------------------------------------------------------INSPECT/CHECK MAXIMUM REMARKS SERVICEABLE LIMITS -------------------------------------------------------------------------------
1. Examine the stow switch and the related hardware for:
 A. Damage  No damage permitted If you find some damage, replace the defective part (Ref. TASK 78-31-18-000-001) and (Ref. TASK 78-31-18-400-001)
 2. Examine the lever of stow switch for :
 A. Crack  No crack permitted If there is crack, replace the stow switch (Ref. TASK 78-31-18-000-001) and (Ref. TASK 78-31-18-400-001)
 F 『 EEFF : ALL E Page 60378-31-18
 E E Feb 01/98 E E ECES E F 『 E C F M E E E E 56-5B E

 

 Stow switch
 Figure 601/TASK 78-31-18-991-301

 F 『 EEFF : ALL E Page 60478-31-18
 E E Feb 01/98 E E ECES E

 F  『
 E  C F M  E
 E  E
 E  56-5B  E
 E  E


 -------------------------------------------------------------------------------INSPECT/CHECK MAXIMUM REMARKS SERVICEABLE LIMITS -------------------------------------------------------------------------------
3. Examine the electrical connector for :
 A. Tightness  The blue mark of the If the blue mark of the stow switch connector stow switch connector can must be covered by the be seen, tighten the blue mark of the electrical harness electrical harness connector with the
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM EXHAUST 1(58)