- the ECAM warning ENG 1(2) REVERSER FAULT appears
- check the T/R test report:
1_ If the following message is present, replace the four deploy
switches (Ref. TASK 78-31-17-000-001) and (Ref. TASK 78-31-17-
400-001) and do the test again:
- "DEPL SW, J5/J6,ECU"
2_ If the following message is present, replace the four stow
switches (Ref. TASK 78-31-18-000-001) and (Ref. TASK 78-31-18-
400-001) and do the test again:
- "STOW SW, J5/J6,ECU"
3_ If the following message is present, replace the four deploy
switches (Ref. TASK 78-31-17-000-001), (Ref. TASK 78-31-17-
400-001) and the four stow switches (Ref. TASK 78-31-18-000-
001), (Ref. TASK 78-31-18-000-001) and do the test again:
- "DPLSTW SW,J5/6,ECU"
4_ If the ECAM warning ENG 1(2) REV PRESSURIZED appears together
with one of the following messages, troubleshoot per (Ref. TSM
78 PB101)
- "HCU(TRPV OPEN)" or "HCU(TRPV), HYD"
5_ If one of the following messages is present, troubleshoot and
do the test again:
- "EIU,HCU" or "TR LOCK, TR ACT"
6_ If the message "HCU (TRPV), HYD" or "HCU, TRSOV, HYD" is
present and if there is no other message above mentioned,
continue the deactivation procedure.
NOTE : The maintenance messages linked to the fault(s)____
occurred before the deactivation, can be recorded in
this T/R test report.
F 『R EEFF : 051-055, 057-057, 059-060, 106-149, E Page 41078-30-00
E E212-299, 301-399, 401-499, Aug 01/05 E E ECES E
F 『
E C F M E
E E
E 56-5B E
E E
(4) Deactivation of the thrust reverser. (Ref. Fig. 402/TASK 78-30-00-991-302, 403/TASK 78-30-00-991-303)
(a) Remove the bolts (3) that attach the lockplates (2) to the storage bracket (4).
(b) Remove the lockplates (2) from the storage bracket (4).
(c) Remove the lockout bolts (1) from the storage bracket (4).
(d) Remove the screws (5) that attach the lockout fairings (6) to the blocker doors.
(e) Attach the lockout fairings (6) to the storage bracket (4) with the screws (5).
(f) TORQUE screws (5) to between 0.16 and 0.19 m.daN (14.15 and 16.81 lbf.in)
(g) Install the lockout bolts (1) on the blocker doors. (Ref. Fig. 403/TASK 78-30-00-991-303)
(h) TORQUE the lockout bolts (1) to between 0.65 and 0.70 m.daN
(57.52 and 61.94 lbf.in).
(5) Put the lockplates (2) over the lockout bolts (1) and install the bolts (3).
(6) TORQUE the bolts (3) to between 0.33 and 0.45 m.daN (29.20 and 39.82 lbf.in).
**ON A/C ALL
Subtask 78-30-00-410-050
B. Close Access
(1) Make sure that the work area is clean and clear of tool(s) and other items.
(2) Remove the access platform(s).
F 『 EEFF : ALL E Page 41178-30-00
E E May 01/05 ERE
ECES E
F 『
E C F M E
E E
E 56-5B E
E E
(3) Close the fan cowl doors: (Ref. TASK 71-13-00-410-040)
FOR 1000EM1
437AL, 438AR
FOR 1000EM2
447AL, 448AR
(4) Remove the warning notice(s).
Subtask 78-30-00-710-051
C. Do a FADEC ground test (Engine Non Motoring) (Ref. TASK 73-29-00-710-040).
(1) Make sure that these fault messages are not in view:
- "STOW SW, J5/J6,ECU" or "DEPL SW,J5/J6,ECU" or "DPLSTW SW,J5/6,ECU"
5. Close-up
________
Subtask 78-30-00-941-051
A. Safety Precautions
(1) In the cockpit, install a warning notice to show the reverser cannot operate.
(2) Make an entry in the log book.
F 『 EEFF : ALL E Page 41278-30-00
E E May 01/05 ERE
ECES E
F 『
E C F M E
E E
E 56-5B E
E E
TASK 78-30-00-440-040
Reactivation of Thrust Reverser
1. Reason for the Job
__________________
Refer to the MMEL TASK: 78-30-01
Thrust Reverser
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific warning notice
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM EXHAUST 1(30)