• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-27 17:14来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
71-13-00-010-040 Opening of the Fan Cowl Doors 71-13-00-410-040 Closing of the Fan Cowl Doors 78-30-00-081-041 Make the Thrust Reverser Serviceable after
 Maintenance 78-30-00-481-041 Make the Thrust Reverser Unserviceable for
 Maintenance 78-30-00-991-305 Fig. 301 78-30-00-991-306 Fig. 302
 F 『 EEFF : ALL E Page 30178-30-00
 E E Feb 01/98 E E ECES E E 56-5B E

 F  『
 E  C F M  E
 E  E


 E E

 3. Job Set-up
__________ Subtask 78-30-00-941-054
 A. Safety Precautions
 (1) On the center pedestal, on the ENG panel 115VU:

 (a) Put a warning notice to tell persons not to start the engine.

 (2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.

 (3) On the overhead maintenance panel 50VU:

 (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.

 (b) Put a warning notice to tell persons not to energize the FADEC 1(2).

 


 Subtask 78-30-00-010-053
 B. Get Access
 (1) Open the fan cowl doors: (Ref. TASK 71-13-00-010-040)
 FOR 1000EM1
 437AL, 438AR
 FOR 1000EM2
 447AL, 448AR

 (2) Put an access platform in position. Subtask 78-30-00-040-051
 C. Make the thrust reverser unserviceable (Ref. TASK 78-30-00-481-041)
 F 『 EEFF : ALL E Page 30278-30-00
 E E Feb 01/98 E E ECES E

 F 『
 E C F M E
 E E
 E 56-5B E
 E E


 4. Procedure
_________
 (Ref. Fig. 301/TASK 78-30-00-991-305, 302/TASK 78-30-00-991-306)
 Subtask 78-30-00-680-050

 A. Drain the pipes of the actuactor system. WARNING : WEAR A FACE SHIELD WHICH IS RESISTANT TO HIGH PRESSURE JETS
_______
 WHEN YOU WORK ON PRESSURIZED SYSTEMS.

 WARNING : IF YOU GET THE FLUID ON YOUR SKIN OR IN YOUR EYES:
_______
 - FLUSH IT AWAY WITH CLEAN WATER
 - GET MEDICAL AID. CAUTION : USE 2 WRENCHES TO REMOVE OR INSTALL THE TUBE COUPLING NUTS.
_______ ONE WRENCH TO HOLD THE UNION AND ONE TO LOOSEN OR TIGHTEN THE COUPLING NUT. THIS WILL PREVENT DAMAGE TO THE HARDWARE.
 CAUTION : MAKE SURE THERE IS NO UNWANTED MATERIAL IN THE PORTS AND
_______
 ORIFICES OR DAMAGE CAN OCCUR.

 CAUTION : YOU MUST INSTALL HYDRAULIC TUBES WITH HYDRAULIC FLUID AS
_______
 LUBRICANT.

 NOTE : The procedure is the same for LH and RH sides.
____
 (1) Put a container 1 USgal (4 l) under the lower blocker door actuator.

 (2) Disconnect the nuts of head and rod supply hoses from the actuator. Let the hydraulic fluid drain completely from the hoses.

 (3) Reconnect the nut of the head supply hose on the lower blocker door actuator.

 (4) TORQUE the nut to between 2.7 and 3.0 m.daN (19.91 and 22.12 lbf.ft)

 (5) Reconnect the nut of the rod supply hose on the lower blocker door actuator.

 (6) TORQUE the nut to between 1.5 and 1.7 m.daN (11.06 and 12.53 lbf.ft)

 (7) Remove the container.


 F 『 EEFF : ALL E Page 30378-30-00
 E E Feb 01/98 E E ECES E F 『 E C F M E E E E 56-5B E

 

 Drain Locations for the Left Door of the Thrust Reverser
 Figure 301/TASK 78-30-00-991-305

 F 『 EEFF : ALL E Page 30478-30-00
 E E Feb 01/98 E E ECES E F 『 E C F M E E E E 56-5B E

 

 Drain Locations for the Right Door of the Thrust Reverser
 Figure 302/TASK 78-30-00-991-306

 F 『 EEFF : ALL E Page 30578-30-00
 E E Feb 01/98 E E ECES E 5. Close-up

 F  『
 E  C F M  E
 E  E
 E  56-5B  E
 E  E


________ Subtask 78-30-00-440-051
 A. Make thrust reverser serviceable (Ref. TASK 78-30-00-081-041). Subtask 78-30-00-410-053
 B. Close Access
 (1) Make sure that the work area is clean and clear of tool(s) and other items.

 (2) Remove the access platform(s).

 (3) Close the fan cowl doors: (Ref. TASK 71-13-00-410-040)
 FOR 1000EM1
 437AL, 438AR
 FOR 1000EM2
 447AL, 448AR


 (4) Remove the warning notice(s).


 F 『 EEFF : ALL E Page 30678-30-00
 E E Feb 01/98 E E ECES E

 F  『
 E  C F M  E
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM EXHAUST 1(26)