acetone (Ref. 70-30-00)
*
isopropyl alcohol (Ref. 70-30-00)
*
stoddard solvent (Ref. 70-30-00)
*
ardrox 552 (Ref. 70-30-00)
*
turco ind 79 (Ref. 70-30-00)
*
mag-chem teksol (Ref. 70-30-00)
*
degreasol 99 R (Ref. 70-30-00)
*
mag-chem skysol (Ref. 70-30-00)
F 『 EEFF : ALL E Page 60178-31-42
E E May 01/05 E E ECES E
F 『
E C F M E
E E
E 56-5B E
E E
C. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
71-13-00-010-040 Opening of the Fan Cowl Doors 71-13-00-410-040 Closing of the Fan Cowl Doors 78-30-00-081-041 Make the Thrust Reverser Serviceable after
Maintenance 78-30-00-481-041 Make the Thrust Reverser Unserviceable for
Maintenance 78-31-00-710-042 Operational Test of the Thrust Reverser System 78-31-00-710-043 Operational Test of the Thrust Reverser without CFDS
- Engine Not Running 78-31-00-710-043 Operational Test of the Thrust Reverser without CFDS
- Engine Running 78-31-42-000-043 Removal of the Left Electrical Harness 78-31-42-000-044 Removal of the Right Electrical Harness 78-31-42-400-043 Installation of the Left Electrical Harness 78-31-42-400-044 Installation of the Right Electrical Harness 78-36-00-010-040 Opening of the Thrust Reverser Doors 78-36-00-410-040 Closing of the Thrust Reverser Doors
3. Job Set-up
__________
Subtask 78-31-42-941-053
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a warning notice to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a warning notice to tell persons not to energize the FADEC 1(2).
F 『 EEFF : ALL E Page 60278-31-42
E E May 01/05 ERE
ECES E Subtask 78-31-42-010-056
F 『
E C F M E
E E
E 56-5B E
E E
B. Get Access
(1) Open the fan cowl doors: (Ref. TASK 71-13-00-010-040) FOR 1000EM1 437AL, 438AR FOR 1000EM2 447AL, 448AR
(2) Put the access platform in position. Subtask 78-31-42-040-053
C. Make the thrust reverser unserviceable (Ref. TASK 78-30-00-481-041). Subtask 78-31-42-010-057
D. Open the thrust reverser doors: (Ref. TASK 78-36-00-010-040)
FOR 1000EM1
451AL, 452AR
FOR 1000EM2
461AL, 462AR
4. Procedure
_________ Subtask 78-31-42-020-053
A. Disconnect the thrust reverser harness electrical connectors.
F 『 EEFF : ALL E Page 60378-31-42
E E May 01/05 ERE
ECES E Subtask 78-31-42-210-050
F 『
E C F M E
E E
E 56-5B E
E E
B. Do a visual inspection of the electrical connectors as follows :
-------------------------------------------------------------------------------INSPECT/CHECK MAXIMUM REMARKS SERVICEABLE LIMITS -------------------------------------------------------------------------------