 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific  warning notice
 B. Consumable Materials
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No.  CP2442  * engine oil (Ref. 70-30-00)
 C. Expendable Parts
 -------------------------------------------------------------------------------FIG.ITEM |DESIGNATION |IPC-CSN -------------------------------------------------------------------------------
R R R 20 30  O-ring O-ring  80-11-10 02 -130 80-11-10 02 -130 

 

 D. Referenced Information

 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
71-13-00-010-040 Opening of the Fan Cowl Doors
 71-13-00-410-040 Closing of the Fan Cowl Doors

R **ON A/C 001-049, 062-099, 101-101, 106-149, 151-199, 204-299, 301-399, R 401-499,
 12-13-80-991-300-A Fig. 301
 **ON A/C 051-061, 102-105, 201-203,
 12-13-80-991-300 Fig. 301A
 **ON A/C ALL

 3. Job Set-up
__________
 Subtask 12-13-80-941-053

 A. Safety Precautions
 (1)
 On the center pedestal, on the ENG panel 115VU:

 (a) Put a warning notice to tell persons not to start the engine.

 (2)
 Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.

 (3)
 On the overhead maintenance panel 50VU:

 (a)
 Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.

 (b)
 Put a warning notice to tell persons not to energize the FADEC 1(2).

 

 


 Subtask 12-13-80-010-053

 B. Open the fan cowl doors: (Ref. TASK 71-13-00-010-040)
 FOR 1000EM1
 437AL, 438AR
 FOR 1000EM2
 447AL, 448AR

 4. Procedure
_________ R **ON A/C 001-049, 062-099, 101-101, 106-149, 151-199, 204-299, 301-399, R 401-499, (Ref. Fig. 301/TASK 12-13-80-991-300-A) **ON A/C 051-061, 102-105, 201-203,
 (Ref. Fig. 301A/TASK 12-13-80-991-300)
 **ON A/C ALL

 Subtask 12-13-80-010-054
 A. Remove the filler plug:
 (1) Remove the filler plug (10), and overflow plug (40). Push inward and simultaneously turn counter clockwise to disengage locking device. Discard O-rings (20 and 30).
 Subtask 12-13-80-610-050
 B. Fill the starter housing
 (1) Fill the starter housing with engine oil (Material No. CP2442) through the filler port until the oil flows from the overflow port.
 NOTE : The quantity of oil used will be less than one quart
____
 (approximately 0.8 l)

 

 Subtask 12-13-80-410-053

 C. Install the filler plug:
R R R  (1) Clean the filler plug (10) and overflow plug (40). Apply a thin layer of engine oil (Material No. CP2442) on the new O-ring (20) and O-ring (30), and install the new O-ring on the filler plug and the overflow plug.
 (2) Install the filler plug (10) and overflow plug (40) push inward and simultaneously turn clockwise to engage locking device.
 5. Close-up________
 Subtask 12-13-80-410-054
 A. Close Access
 (1) Make sure that the work area is clean and clear of tool(s) and other items.
 (2) Close the fan cowl doors: (Ref. TASK 71-13-00-410-040) FOR 1000EM1 437AL, 438AR FOR 1000EM2 447AL, 448AR
 (3) Remove the warning notice(s).

 

 GAS - DESCRIPTION AND OPERATION
_______________________________
 1. General
_______
R **ON A/C 001-049, 101-149, 151-199, 201-299, 301-399, 401-499,
 This section gives information about the servicing of the:
 -Hydraulic Power (Refer to 12-14-29 Page 301),
 -Landing Gear (Refer to 12-14-32) Page 301),
 **ON A/C 051-099,
 This section gives information about the servicing of the:
 -Hydraulic Power (Refer to 12-14-29 Page 301),
 -Landing Gear (Refer to 12-14-32) Page 301),
 -Oxygen (Refer to 12-14-35 Page 301).


 HYDRAULIC POWER - SERVICING
___________________________ TASK 12-14-29-614-001 Fill the Hydraulic Power Accumulators 1070GM/2070GM/3070GM with Nitrogen WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM SERVICING 1(90)