SURGICAL PROTOCOL
Z1-Connect
9a - Take the cover screw out
of its housing. Maintain the
screwdriver up while the screw is
moved to the surgical site. Seal
the implant with the cover screw
Note : If the implant insertion is not com- 10a - Suture the gingiva
plete with the contra-angle, finalize the
insertion with the ratchet wrench and its
screwtool.
Note: If the implant requires more than 50Ncm to
insert into the bone, carefully remove the implant
and tap the bone using the screw tap. Then
re-insert the implant using the above protocol.
10b - Take the cover screw
out of its housing. Maintain the
screwdriver up while the screw is
moved to the surgical site. Seal the
implant with the cover screw
9b - Remove the ratchet wrench 11b - Suture the gingiva
and vertically remove the
screwtool
Note: If the implant requires more than 50Ncm
to insert into the bone, carefully remove the
implant and tap the bone using the screw tap.
Then re-insert the implant using the above
protocol
4 - Use the drill :
#3 for Ø 3.5 implants
#3 then 4 for Ø 4 implants
#3, 4 then 5 for Ø 5 implants
5 -
Use screw tap Ø 3,5 for Ø 3.5 implants
Use screw tap Ø 4 for Ø 4 implants
Use screw tap Ø 5 for Ø 5 implants
3 - Use drill #2 up to the
required mark
20
Screw-retained conical head
Titanium base + castable ring + screw.
Z1-CONNECT SYSTEM
8 possible positions– Anti-unscrewing system.
Anti-unscrewing system.
Anti-unscrewing system.
Plastic castable screw-retained abutment + screw
Gold cast-to screw-retained abutment + screw with plastic sleeve
Titanium abutment + screw
25°
ZC-MT002
15°
ZC-MT001

For all implant diameters ZC-MT000
COMMENTS : Anti-unscrewing system : the system is activated with a 30 Newtons . cm torque (use the torque wrench, or
torque screw-tool see p.13).
PROSTHETIC COMPONENTS
For Ø 3,5 and 4 mm implants
For Ø 5 mm implants
O-MS500
O-MS600
For Ø 3,5 and 4 mm implants
For Ø 5 mm implants
ZC-PC400
ZC-PC500
For Ø 3,5 and 4 mm implants
For Ø 5 mm implants
O-MC500
O-MC600
Zirconnect
21
Castable bar
Castable bar BC019
PROSTHETIC COMPONENTS
Clip
Steel clip
Gold clip
CA020
CO020
Spherical attachment
Cap
Height 5 mm
For all implant diameters O-ASC550
O’ring
Height 5 mm
For all implant diameters O-ASO550
Temporary abutment
For all implant diameters ZC-MP000
Z1-Connect
2.7
2.7
22
PROSTHETIC ACCESSORIES
For all implant diameters HAS001
Spherical attachment analog
For all implant diameters VTD185
Laboratory screw
Conical head analog
For Ø 3,5 mm and 4 mm implants HP400
For Ø 5 mm implants HP500
Implant analog
For Ø 3,5 mm and 4 mm implants O-RL500
For Ø 5 mm implants O-RL600
For an easy and accurate laboratory impression
Copping for screw-retained abutment
0° 15° et 25°
For Ø 3,5 mm and 4 mm implants CZ400 CZ401
For Ø 5 mm implants CZ500 CZ501
Zirconnect
23
PROSTHETIC ACCESSORIES
Transfer for conical head - indirect technique : Pop-in
For Ø 3,5 mm and 4 mm implants ZC-TIP400
For Ø 5 mm implants ZC-TIP500
Transfer for conical head - direct technique : Pick-up
For Ø 3,5 mm and 4 mm implants ZC-TDP400
For Ø 5 mm implants ZC-TDP500
Transfer - SwissClip technique
Z1-Connect
Transfer - indirect technique : Pop-in
For Ø 3,5 mm and 4 mm implants ZC-TD000
For Ø 5 mm implants ZC-TD600
For Ø 3,5 mm and 4 mm implants ZC-TDC500
For Ø 5 mm implants ZC-TDC600
Transfer - direct technique : Pick-up
For Ø 3,5 mm and 4 mm implants ZC-TI000
For Ø 5 mm implants ZC-TI600
24
Transfer
Direct technique
(Pick-in)
Transfer
SwissClip technique
Transfer
Indirect technique
(Pop-in)
Cemented crown and
bridge application.
Titanium or MCB
abutment
Cemented crown and
bridge application.
Plastic castable
screw-retained abutment.
Cemented crown and
bridge application.
Gold cast-to screwretained
abutment
with plastic sleeve
Zirconnect PROSTHETIC PROTOCOL
25
PROSTHETIC PROTOCOL
 