Box for osteotomes
Composition :
Torque wrench – Serrage 30N.cm
Hexagonal tip for torque wrench
Short hexagonal screwdriver
Long hexagonal screwdriver
Short hexagonal screwtool
Long hexagonal screwtool
0° abutment angulation kit
15° abutment angulation kit
25° abutment angulation kit
Prosthetic box
14
Direct or indirect
transfer
Plastic castable or
cast-to gold abutment
Plastic castable or
cast-to gold abutment
Direct or indirect
conical transfer
Conical base or
spherical base
Conical base
Direct or indirect
conical transfer
Conical or spherical
analog
Conical analog
Cap
or O’ring
Plastic castable or
cast-to gold copping
Plastic castable or
cast-to gold copping
Direct or indirect
transfer
Cemented crown and bridge
prosthetic application
Fixed detachable
prosthetic application
Overdenture
prosthetic application
Titanium
abutment
0°,15°,25°
Analog Analog
Zirconnect Z1-CONNECT CONSPECTUS
15
13
1 stage implant with zirconia-titanium collar -
internal octagonal connection
Implants and Surgical components
Surgical protocol
Prosthetic components
Prosthetic accessories
Prosthetic protocol
p 17
p 19
p 21
p 23
p 25
Z1-CONNECT SYSTEM
Z1-Connect
16
Z1-CONNECT SYSTEM
1 surgical stage implants - zirconia-titanium collar
IMPLANTS AND SURGICAL COMPONENTS
Z1-Connect implant : diameter 3.5 mm – height of the trans-gingival collar : 1.5 mm
L : 8 mm
ZBX308
L : 10,5 mm
ZBX310
L : 13 mm
ZBX313
L : 15,5 mm
Ø 3,5 mm ZBX315
Z1-Connect implant : diameter 4 mm – height of the trans-gingival collar : 1,5 mm
L : 8 mm
ZBX408
L : 10,5 mm
ZBX410
L : 13 mm
ZBX413
L : 15,5 mm
Ø 4 mm ZBX415
Z1-Connect implant : diameter 5 mm – height of the trans-gingival collar : 1,5 mm
L : 8 mm
ZBX508
L : 10,5 mm
ZBX510
L : 13 mm
ZBX513
L : 15,5 mm
Ø 5 mm ZBX515
Height 3 mm Height 5 mm
For implants Ø 3,5 and 4 mm ZC-VT530 ZC-VT550
For implants Ø 5 mm ZC-VT630 ZC-VT650
Cover cap
Zirconnect
17
COMMENTS : ZT-Hybrid body surface : smooth zirconia collar
Every implant is delivered with a surgical healing screw (see liste page 17)
IMPLANTS AND SURGICAL COMPONENTS
Z1-Connect implant : diameter 4 mm – height of the trans-gingival collar : 2.5 mm
L : 8 mm
ZHX408
L : 10,5 mm
ZHX410
L : 13 mm
ZHX413
L : 15,5 mm
Ø 4 mm ZHX415
Z1-Connect implant : diameter 3.5 mm – height of the trans-gingival collar : 2.5 mm
L : 8 mm
ZHX308
L : 10,5 mm
ZHX310
L : 13 mm
ZHX313
L : 15,5 mm
Ø 3,5 mm ZHX315
Z1-Connect implant : diameter 5 mm – Height of the trans-gingival collar : 2.5 mm
L : 8 mm
ZHX508
L : 10,5 mm
ZHX510
L : 13 mm
ZHX513
L : 15,5 mm
Ø 5 mm ZHX515
Z1-Connect
18
SURGICAL PROTOCOL
Ratchet wrench
protocol
Contra-angle
protocol
6a - Take the screwtool for
the contra-angle and clamp
the implant inside its housing.
Maintain the contraangle
up when the implant is
moved to the surgical site
7a - Insert the implant into
the prepared site until the
end of the most coronal
microthread
Note : It is recommended
not exceed a tightening
torque above 50 Ncm
8a - Vertically remove the
contra-angle and the contraangle
screwtool
6b - Take the screwtool and
clamp the implant inside its
housing. Maintain the screwtool
up when the implant is
moved to the surgical site
7b - Begin to manually
insert the implant into the
prepared site
Note : It is recommended
not exceed a tightening
torque above 50 Ncm
8b - Complete the implant
insertion with the ratchet
wrench until the end of the
most coronal microthread
Drilling
protocol
Note : The implant choice (diameter and
length) will be done thanks to the T.B.R.®
Zirconnect ® scanora and X-ray template
(notice of the 1.0 mm drills point when you
are evaluating the available bone height).
1 - Initiate crestal bone
penetration with the round
pilot drill
2 - Use the stop drill #1
adapted to the implant length
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:航空资料40(73)