VANE  MAX DEPTH  
AREA  SERVICE LIMIT  
A  0.030 (0.762 mm)  
B  0.010 (0.254 mm)  
C  0.030 (0.762 mm) 
IGV THRU 7TH-STAGE HPC VANES  L-A5172 
HPC Vane Continue-In-Service Limits 
Figure 613 (Sheet 1)
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 72-00-00
 ALL  ú ú N02 Page 680U ú Jun 18/00 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
////////////////////////A / PW4000 SERIES /747-400 / ENGINES /MAINTENANCE MANUAL ////////////////////////
THESE DIMENSIONS CONTROLLED BY DEPTH LIMITS 
B-B 
8TH-STAGE HPC VANE 
L-A5178 
HPC Vane Continue-In-Service Limits Figure 613 (Sheet 2)
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 72-00-00
 ALL  ú ú N02 Page 680V ú Jun 18/00 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
9TH- AND 10TH-STAGE HPC VANES L-A5192 
HPC Vane Continue-In-Service Limits Figure 613 (Sheet 3) 
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 72-00-00
 ALL  ú 
 ú  N02  Page 680W 
 ú  Jun 18/00 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
////////////////////////A / PW4000 SERIES /747-400 / ENGINES /MAINTENANCE MANUAL //////////////////////// 
12TH-STAGE VANE
WHEN DIMENSION A OR C IS 0.000, USE THESE DIMENSIONS TO FIND DISTANCE B 
VANE  MAX DEPTH SERVICE LIMIT  
AREA  A  B  C  
11/12  10%  0.000 INCH (0.000 mm)  0.010 INCH (0.254 mm)  0.000 INCH (0.000 mm)  
80%  0.030 INCH (0.762 mm)  0.010 INCH (0.254 mm)  0.030 INCH (0.762 mm)
THESE DIMENSIONS CONTROLLED BY DEPTH LIMITS 
D-D 
11TH- AND 12TH-STAGE HPC VANES  L-A5179 
HPC Vane Continue-In-Service Limits Figure 613 (Sheet 4) 
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 72-00-00
 ALL  ú ú N02 Page 680X ú Jun 18/00 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
13TH-STAGE VANE
WHEN DIMENSION A OR C IS 0.000, USE THESE DIMENSIONS TO FIND DISTANCE B 
VANE  MAX DEPTH SERVICE LIMIT  
AREA  A  B  C  
13/14  10%  0.000 INCH (0.000 mm)  0.010 INCH (0.254 mm)  0.000 INCH (0.000 mm)  
80%  0.030 INCH (0.762 mm)  0.010 INCH (0.254 mm)  0.030 INCH (0.762 mm)
THESE DIMENSIONS CONTROLLED BY DEPTH LIMITS 
E-E 
13TH- AND 14TH-STAGE HPC VANES 
L-A5185 
HPC Vane Continue-In-Service Limits Figure 613 (Sheet 5) 
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 72-00-00
 ALL  ú ú N02 Page 680Y ú Jun 18/00 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
////////////////////////A / PW4000 SERIES /747-400 / ENGINES /MAINTENANCE MANUAL //////////////////////// 
F
LEADING EDGE 
VANE AREA  MAX DEPTH SERVICE LIMIT  
A  0.030 INCH (0.762 mm)  
B  0.010 INCH (0.254 mm)  
C  0.030 INCH (0.762 mm) 
15TH-STAGE HPC EXIT STATOR VANE 
L-A5199 HPC Vane Continue-In-Service Limits Figure 613 (Sheet 6)
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 72-00-00
 ALL  ú ú N02 Page 680Z ú Jun 18/00 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 发动机 ENGINE 1(67)