S 016-326-N00
(3)
Open the core cowl panel (AMM 71-11-06/201).
S 016-327-N00
WARNING: DO THE THRUST REVERSER DEACTIVATION PROCEDURE TO PREVENT
_______ THE OPERATION OF THE THRUST REVERSER. THE ACCIDENTAL OPERATION OF THE THRUST REVERSER CAN CAUSE INJURIES TO PERSONS OR DAMAGE TO EQUIPMENT.
(4)
Open the thrust reverser (AMM 78-31-00/201).
E.
Procedure
S 226-227-N00
(1) If the engine had an IFSD at power because of one or more of the causes that follow, remove the engine (AMM 71-00-02/401) and examine it:
NOTE: Refer to the PW4000 Engine Manual to perform a complete
____
inspection of all bearing compartments.
(a)
Oil pressure reading below 40 psi (276.0 kPa).
(b)
High oil temperature reading (AMM 71-00-00/201: Engine Operating Limits).
(c)
The oil temperature was too high (AMM 71-00-00/201: Engine Operating Limits).
NOTE: Do the Oil Overtemperature Inspection (AMM
____
72-00-00/601).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
72-00-00
ALL ú ú N01 Page 633 ú Feb 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
////////////////////////A / PW4000 SERIES /747-400 / ENGINES/MAINTENANCE MANUAL ////////////////////////
No. 6 - Engine Windmilling Inspection/Check
___________________________________________
(d)
Interrupted oil supply for more than 10 seconds.
(e)
Engine operated or windmilled without oil (i.e., no oil in system, or oil pump shaft failure).
S 226-228-N00
(2) If the oil pressure was continuously more than zero, during the engine windmilling (after an IFSD), do the inspections that follow:
NOTE: During windmilling, the oil pressure indications can be
____ low or unreadable, (below 40 psi (276.0 kPa) which is permissible if oil temperature conditions are within limits (AMM 71-00-00/201: Engine Operating Limits).
(a) Examine the main oil filter element (AMM 79-21-05/601) and the magnetic chip detectors (AMM 79-21-10/601) for contamination (chips). 1) If you find some metal particles, keep the particles and do
the Oil System Contamination Inspection (AMM 72-00-00/601) prior to further flight.
2) If no chips are found on oil filter or on any of the six chip detectors, reinstall the magnetic chip detectors and a cleaned oil filter (AMM 79-21-05/401, 79-21-10/401).
(b)
Do the Engine Oil Servicing procedure (AMM 12-13-03/301).
(c)
Close the thrust reverser (AMM 78-31-00/201).
(d)
Close the core cowl panel (AMM 71-11-06/201).
(e)
Close the fan cowl panel (AMM 71-11-04/201).
(f)
Start the engine (AMM 71-00-00/201).
(g)
Operate the engine at minimum power for five minutes.
(h)
Do the engine shutdown procedure (AMM 71-00-00/201).
(i)
Open the fan cowl panel (AMM 71-11-04/201).
WARNING: DO THE THRUST REVERSER DEACTIVATION PROCEDURE TO PREVENT
_______ THE OPERATION OF THE THRUST REVERSER. THE ACCIDENTAL OPERATION OF THE THRUST REVERSER CAN CAUSE INJURIES TO PERSONS OR DAMAGE TO EQUIPMENT.
(j) Do this procedure: Thrust Reverser Deactivation for Ground Maintenance (AMM 78-31-00/201).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
72-00-00
ALL ú ú N01 Page 634 ú Feb 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
No. 6 - Engine Windmilling Inspection/Check
___________________________________________
(k) Open the core cowl panel (AMM 71-11-06/201).
WARNING: OBEY THE INSTRUCTIONS IN 78-31-00 WHEN YOU OPEN THE THRUST
_______ REVERSERS. IF YOU DO NOT OBEY THE INSTRUCTIONS, INJURIES TO PERSONS OR DAMAGE TO EQUIPMENT CAN OCCUR.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 发动机 ENGINE 1(39)