3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the LAND CAT III capability (Ref. AMM TASK 22-97-00-710-001).
4. Fault Isolation
_______________
A. On the MCDU 1, if the LAND TEST REFUSED message comes into view:
- replace the FMGC-1 (1CA1) (Ref. AMM TASK 22-83-34-000-001) and (Ref. AMM TASK 22-83-34-400-001).
(1) If the fault continues:
- replace the LGCIU-1 (5GA1) (Ref. AMM TASK 32-31-71-000-001) and (Ref. AMM TASK 32-31-71-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-83-00∞∞∞∞∞∞∞∞∞∞Page A205
Aug 01/05R CES
(2) If the fault continues:
- replace the LGCIU-2 (5GA2) (Ref. AMM TASK 32-31-71-000-001) and (Ref. AMM TASK 32-31-71-400-001).
(3) If the fault continues:
- do a check of the wiring of the NOSE GEAR OWN discrete from the FMGC 1 (1CA1) to the LGCIU 1 (5GA1)
- do a check of the wiring of the NOSE GEAR OPP discrete from the
FMGC 1 (1CA1) to the LGCIU 2 (5GA2)
(Ref. ASM 22-85/04).
(a) If there is no continuity:
- repair the above wiring.
(b) If there is continuity:
- do a check of the wiring of the ENG OWN STOP and ENG OPP STOP discretes (from the FMGC 1 (1CA1) to the diode module (1801VD)) (Ref. ASM 22-85/04).
1 If there is no continuity:
_ - repair the above wiring.
2 If there is continuity:
_
- do a check of the wiring of the diode module 1801VD from pin A/10 and from pin A/11 to the first terminal block (Ref. ASM 22-85/04).
a If there is no continuity:
_ - repair the above wiring.
b If there is continuity:
_ - replace the DIODE MODULE (1801VD).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-83-00∞∞∞∞∞∞∞∞∞∞Page A206
Aug 01/05R
CES Loss of the Ground Conditions on the FMGC 2
1. Possible Causes
_______________
- FMGC-2 (1CA2)
- LGCIU-1 (5GA1)
- LGCIU-2 (5GA2)
- wiring of the NOSE GEAR OWN discrete from the FMGC 2 (1CA2) to the LGCIU 2 (5GA2)
- wiring of the NOSE GEAR OPP discrete from the FMGC 2 (1CA2) to the LGCIU 1 (5GA1)
- wiring of the ENG OWN STOP and ENG OPP STOP discretes (from the FMGC 2 (1CA2) to the diode modules (1800VD and 1801VD))
- wiring of the diode module 1800VD
- wiring of the diode module 1801VD
- DIODE MODULE (1800VD)
- DIODE MODULE (1801VD)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 22-83-34-000-001 Removal of the FMGC (1CA1,1CA2)
AMM 22-83-34-400-001 Installation of the FMGC (1CA1,1CA2)
AMM 22-97-00-710-001 Operational Test of the LAND CAT III Capability
AMM 32-31-71-000-001 Removal of the LGCIU (5GA1, 5GA2)
AMM 32-31-71-400-001 Installation of the LGCIU (5GA1, 5GA2)
ASM 22-85/04
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the LAND CAT III capability (Ref. AMM TASK 22-97-00-710-001).
4. Fault Isolation
_______________
A. On the MCDU 2, if the LAND TEST REFUSED message comes into view:
- replace the FMGC-2 (1CA2) (Ref. AMM TASK 22-83-34-000-001) and (Ref. AMM TASK 22-83-34-400-001).
(1) If the fault continues:
- replace the LGCIU-1 (5GA1) (Ref. AMM TASK 32-31-71-000-001) and (Ref. AMM TASK 32-31-71-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-83-00∞∞∞∞∞∞∞∞∞∞Page A207
Aug 01/05R CES
(2) If the fault continues:
- replace the LGCIU-2 (5GA2) (Ref. AMM TASK 32-31-71-000-001) and (Ref. AMM TASK 32-31-71-400-001).
(3) If the fault continues:
- do a check of the wiring of the NOSE GEAR OWN discrete from the FMGC 2 (1CA2) to the LGCIU 2 (5GA2) 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 AUTO FLIGHT 自动飞行2(95)