3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU EIS/DMC1/SPLY 10WT1 E11 49VU EIS/DMC1/SWTG 21WT1 E09
B. Test
(1) Do the Ground Scanning of the AFS (Ref. AMM TASK 22-91-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message AFS: CHK DMC1-FMGC1 CKT:
- replace the FMGC-1 (1CA1) (Ref. AMM TASK 22-83-34-000-001) and (Ref. AMM TASK 22-83-34-400-001).
(1) If the fault continues:
- replace the DMC-1 (1WT1) (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-83-00∞∞∞∞∞∞∞∞∞∞Page 287
Aug 01/05R CES
(2) If the fault continues:
- do a check and repair the wiring of the PFD OWN VALID discrete (from the FMGC 1 (1CA1) to the DMC 1 (1WT1)) (Ref. ASM 22-85/04).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-83-00∞∞∞∞∞∞∞∞∞∞Page 288
Aug 01/05R
CES Loss of the Reception of the DMC 1 VALID Discrete by the FMGC 2
1. Possible Causes
_______________
- FMGC-2 (1CA2)
- wiring of the PFD OPP VALID discrete (from the FMGC 2 (1CA2) to the first terminal block)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 22-83-34-000-001 Removal of the FMGC (1CA1,1CA2)
AMM 22-83-34-400-001 Installation of the FMGC (1CA1,1CA2)
AMM 22-91-00-710-001 Ground Scanning of the AFS
ASM 22-85/04
3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU EIS/DMC1/SPLY 10WT1 E11 49VU EIS/DMC1/SWTG 21WT1 E09
B. Test
(1) Do the Ground Scanning of the AFS (Ref. AMM TASK 22-91-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message AFS: CHK DMC1-FMGC2 CKT:
- replace the FMGC-2 (1CA2) (Ref. AMM TASK 22-83-34-000-001) and (Ref. AMM TASK 22-83-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring of the PFD OPP VALID discrete (from the FMGC 2 (1CA2) to the first terminal block) (Ref. ASM 22-85/04).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-83-00∞∞∞∞∞∞∞∞∞∞Page 289
Aug 01/05R CES
Loss of the Reception of the DMC 2 VALID Discrete by the FMGC 2
1. Possible Causes
_______________
- FMGC-2 (1CA2)
- wiring of the PFD OWN VALID discrete (from the FMGC 2 (1CA2) to the first terminal block)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 22-83-34-000-001 Removal of the FMGC (1CA1,1CA2)
AMM 22-83-34-400-001 Installation of the FMGC (1CA1,1CA2)
AMM 22-91-00-710-001 Ground Scanning of the AFS
ASM 22-85/04
3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU EIS/DMC2/SPLY 10WT2 Q08 121VU EIS/DMC2/SWTG 21WT2 R08
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 AUTO FLIGHT 自动飞行2(89)