3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the LAND CAT III capability (Ref. AMM TASK 22-97-00-710-001).
4. Fault Isolation
_______________
A. Table of the circuit breakers used in this procedure:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU AUTO FLT/FCU/1 9CA1 B05 49VU AUTO FLT/FMGC/1 10CA1 B02 121VU AUTO FLT/FCU/2 9CA2 M21
B. If the test gives the maintenance message AFS : CHK FMGC1 (FCU INPUT): - open the circuit breakers 9CA1, 9CA2 and 10CA1
- after 15 s, close these circuit breakers
- do the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001) and read the result for the FMGC 1.
(1) If the test gives one maintenance message:
- refer to the procedure related to this message.
C. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-83-00∞∞∞∞∞∞∞∞∞∞Page A200
Aug 01/05R CES
Loss of the FCU Information on the FMGC 2
1. Possible Causes
_______________
- FMGC 2
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 22-96-00-710-001 Operational Test of the AFS
AMM 22-97-00-710-001 Operational Test of the LAND CAT III Capability
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the LAND CAT III capability (Ref. AMM TASK 22-97-00-710-001).
4. Fault Isolation
_______________
A. Table of the circuit breakers used in this procedure:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
49VU AUTO FLT/FCU/1 9CA1 B05 121VU AUTO FLT/FCU/2 9CA2 M21 121VU AUTO FLT/FMGC/2 10CA2 M17
B. If the test gives the maintenance message AFS : CHK FMGC2 (FCU INPUT): - open the circuit breakers 9CA1, 9CA2 and 10CA2
- after 15 s, close these circuit breakers
- do the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001) and read the result for the FMGC 2.
(1) If the test gives one maintenance message:
- refer to the procedure related to this message.
C. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-83-00∞∞∞∞∞∞∞∞∞∞Page A201
Aug 01/05R CES
Loss of the FWC Functions
1. Possible Causes
_______________
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 22-97-00-710-001 Operational Test of the LAND CAT III Capability
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the LAND CAT III capability (Ref. AMM TASK 22-97-00-710-001).
4. Fault Isolation
_______________
A. Table of the circuit breakers used in this procedure:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU FWS/FWC1/SPLY 3WW F01 121VU EIS/FWC2/SPLY 2WW Q07
B. If the test gives the maintenance message AFS : CHK FWC 1/2 (INST SYS): - open the circuit breakers 2WW and 3WW
- after 15 s, close these circuit breakers
- do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-83-00∞∞∞∞∞∞∞∞∞∞Page A202
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 AUTO FLIGHT 自动飞行2(93)