- wiring of the LGCIU OWN bus from the FAC 1 (1CC1) to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 22-66-34-000-002 Removal of the FAC (1CC1,1CC2)
AMM 22-66-34-400-002 Installation of the FAC (1CC1,1CC2)
AMM 22-91-00-710-001 Ground Scanning of the AFS
ASM 22-69/01
3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU L/G/LGCIU/SYS1/NORM 1GA C09 121VU HYDRAULIC/LGCIU/SYS1/GRND SPLY 52GA Q34
B. Test
(1) Do the Ground Scanning of the AFS (Ref. AMM TASK 22-91-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message AFS: LGCIU1:
- replace the FAC-1 (1CC1) (Ref. AMM TASK 22-66-34-000-002) and (Ref. AMM TASK 22-66-34-400-002).
(1) If the fault continues:
- do a check and repair the wiring of the LGCIU OWN bus from the FAC1 (1CC1) to the first terminal block (Ref. ASM 22-69/01).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-66-00∞∞∞∞∞∞∞∞∞∞Page 235
May 01/04 CES Loss of the Reception of the LGCIU 2 Bus by the FAC 2
1. Possible Causes
_______________
- FAC-2 (1CC2)
- wiring of the LGCIU OWN bus from the FAC 2 (1CC2) to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 22-66-34-000-002 Removal of the FAC (1CC1,1CC2)
AMM 22-66-34-400-002 Installation of the FAC (1CC1,1CC2)
AMM 22-91-00-710-001 Ground Scanning of the AFS
ASM 22-69/01
3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
121VU HYDRAULIC/LGCIU/SYS2 2GA Q35
B. Test
(1) Do the Ground Scanning of the AFS (Ref. AMM TASK 22-91-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message AFS: LGCIU2:
- replace the FAC-2 (1CC2) (Ref. AMM TASK 22-66-34-000-002) and (Ref. AMM TASK 22-66-34-400-002).
(1) If the fault continues:
- do a check and repair the wiring of the LGCIU OWN bus from the FAC2 (1CC2) to the first terminal block (Ref. ASM 22-69/01).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-66-00∞∞∞∞∞∞∞∞∞∞Page 236
Feb 01/98 CES Loss of the Data from the ADIRUs to the AFS
1. Possible Causes
_______________
- FAC-1 (1CC1)
- FAC-2 (1CC2)
- FMGC-1 (1CA1)
- FMGC-2 (1CA2)
- wiring of the ADC SW and ATT SW discretes (from the FAC 1 (1CC1) to the first terminal block)
- wiring of the ADC SW and ATT SW discretes (from the FAC 2 (1CC2) to the first terminal block)
- wiring of the ADC 3 SW and ATT 3 SW discretes (from the FMGC 1 (1CA1) to the first terminal block)
- wiring of the ADC SW and ATT SW discretes (from the FMGC 2 (1CA2) to the first terminal block)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 22-66-34-000-002 Removal of the FAC (1CC1,1CC2)
AMM 22-66-34-400-002 Installation of the FAC (1CC1,1CC2)
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 AUTO FLIGHT 自动飞行2(11)