- Install the OBRM A13 on the FMGC1(2),
- Close the circuit breaker 10CA1(2).
B. Do the Operational Test of the AFS (Ref. AMM TASK 22-96-00-710-001).
Aug 01/05R CES
CAT 2 (INOP SYS) on the SD
1. Possible Causes
_______________
- PFD-CAPT (2WT1)
- DMC-1 (1WT1)
- PFD-F/O (2WT2)
- DMC-2 (1WT2)
- wiring of the PFD OWN VALID discrete from the DMC 1 (1WT1) to the first terminal block
- wiring of the PFD OPP VALID discrete from the DMC 2 (1WT2) to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 22-97-00-710-001
AMM 31-63-22-000-001
AMM 31-63-22-400-001
AMM 31-63-34-000-001
AMM 31-63-34-400-001
ASM 22-85/04
3. Fault Confirmation
__________________
Operational Test of the LAND CAT III Capability
Removal of the Display Unit
(2WT1,2WT2,3WT1,3WT2,4WT1,4WT2)
Installation of the Display Unit
(2WT1,2WT2,3WT1,3WT2,4WT1,4WT2)
Removal of the DMC (1WT1,1WT2,1WT3)
Installation of the DMC (1WT1,1WT2,1WT3)
A. Do the Operational Test of the LAND CAT III Capability (Ref. AMM TASK 22-97-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance messages:
AFS: CHK DMC 1 - FMGC 1 CKT (ISSUED BY: FG1) and
AFS: CHK DMC 1 - FMGC 2 CKT (ISSUED BY: FG2)
(1) Do the test given in Para. 3 with the EIS DMC selector switch (18WT) on the SWITCHING panel (8VU) at CAPT/3.
(a) If the fault continues:
- replace the PFD-CAPT (2WT1) (Ref. AMM TASK 31-63-22-000-001) and (Ref. AMM TASK 31-63-22-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-83-00∞∞∞∞∞∞∞∞∞∞Page A238
Aug 01/05 CES
(2) If the fault continues:
- replace the DMC-1 (1WT1) (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).
(3) If the fault continues:
- do a check and repair the wiring of the PFD OWN VALID discrete from the DMC 1 (1WT1) to the first terminal block (Ref. ASM 22-85/04).
B. If the test gives the maintenance messages:
AFS: CHK DMC 2 - FMGC 2 CKT (ISSUED BY: FG2) and
AFS: CHK DMC 2 - FMGC 1 CKT (ISSUED BY: FG1)
(1) Do the test given in Para. 3 with the EIS DMC selector switch (18WT) on the SWITCHING panel (8VU) at F/O/3.
(a) If the fault continues:
- replace the PFD-F/O (2WT2) (Ref. AMM TASK 31-63-22-000-001) and (Ref. AMM TASK 31-63-22-400-001).
(2) If the fault continues:
- replace the DMC-2 (1WT2) (Ref. AMM TASK 31-63-34-000-001) and (Ref. AMM TASK 31-63-34-400-001).
(3) If the fault continues:
- do a check and repair the wiring of the PFD OPP VALID discrete from the DMC 2 (1WT2) to the first terminal block (Ref. ASM 22-85/04).
C. Do the test given in Para. 3.