- replace the ELAC-2 (2CE2) (Ref. AMM TASK 27-93-34-000-001) and (Ref. AMM TASK 27-93-34-400-001).
(2) If the fault continues:
- do a check and repair the wiring of the ELAC OWN AP DISC MON and ELAC OWN AP DISC COM discretes from the FMGC 2 (1CA2) to the ELAC 2 (2CE2) (Ref. ASM 22-85/04).
E. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-66-00∞∞∞∞∞∞∞∞∞∞Page 264
Feb 01/03R CES
Loss of the Reception of the SFCC 1 Bus by the FAC 1
1. Possible Causes
_______________
- FAC-1 (1CC1)
- wiring of the SFCC OWN bus from the FAC 1 (1CC1) to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 22-66-34-000-002 Removal of the FAC (1CC1,1CC2)
AMM 22-66-34-400-002 Installation of the FAC (1CC1,1CC2)
AMM 22-91-00-710-001 Ground Scanning of the AFS
ASM 22-69/01
3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU FLIGHT CONTROLS/SLT/CTL AND MONG/SYS1 5CV B06
B. Test
(1) Do the Ground Scanning of the AFS (Ref. AMM TASK 22-91-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message AFS: SFCC1:
- replace the FAC-1 (1CC1) (Ref. AMM TASK 22-66-34-000-002) and (Ref. AMM TASK 22-66-34-400-002).
(1) If the fault continues:
- do a check and repair the wiring of the SFCC OWN bus from the FAC 1 (1CC1) to the first terminal block (Ref. ASM 22-69/01).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-66-00∞∞∞∞∞∞∞∞∞∞Page 265
Feb 01/03R CES
Loss of the Reception of the SFCC 2 Bus by the FAC 2
1. Possible Causes
_______________
- FAC-2 (1CC2)
- wiring of the SFCC OWN bus from the FAC 2 (1CC2) to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 22-66-34-000-002 Removal of the FAC (1CC1,1CC2)
AMM 22-66-34-400-002 Installation of the FAC (1CC1,1CC2)
AMM 22-91-00-710-001 Ground Scanning of the AFS
ASM 22-69/01
3. Fault Confirmation
__________________
A. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
121VU FLIGHT CONTROLS/SLT/CTL/SYS2 7CV R21
B. Test
(1) Do the Ground Scanning of the AFS (Ref. AMM TASK 22-91-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message AFS: SFCC2:
- replace the FAC-2 (1CC2) (Ref. AMM TASK 22-66-34-000-002) and (Ref. AMM TASK 22-66-34-400-002).
(1) If the fault continues:
- do a check and repair the wiring of the SFCC OWN bus from the FAC 2 (1CC2) to the first terminal block (Ref. ASM 22-69/01).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-66-00∞∞∞∞∞∞∞∞∞∞Page 266
Feb 01/03R CES
Loss of the Reception of the SFCC 1 SLATS EXTD Discrete by the FAC 1
1. Possible Causes
_______________
- FAC-1 (1CC1)
- wiring of the SLATS EXTD discrete from the FAC 1 (1CC1) to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 AUTO FLIGHT 自动飞行2(22)