• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 09:22来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
AMM 22-66-34-000-002 Removal of the FAC (1CC1,1CC2)
 AMM 22-66-34-400-002 Installation of the FAC (1CC1,1CC2)
 AMM 22-96-00-710-001 Operational Test of the AFS
 ASM 22-86/02

 3. Fault Confirmation
__________________
 A. Test
 (1) Do the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001) and read the result for the FAC 2.
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message AFS: FAC2/FMGC2 BUS WIRG:
 - replace the FAC-2 (1CC2), (Ref. AMM TASK 22-66-34-000-002) and (Ref. AMM TASK 22-66-34-400-002).
 (1) If the fault continues:
 - do a check and repair the wiring of the FMGC OWN B bus from the FAC 2 (1CC2) to the first terminal block, (Ref. ASM 22-86/02).
 B. Do the test given in Para. 3.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-66-00∞∞∞∞∞∞∞∞∞∞Page 232
 May 01/04 CESR **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,


 TASK 22-66-00-810-829
 Loss of the Parity Pin Program on the FAC 1
 1. Possible Causes
_______________
 - FAC-1 (1CC1)

 - wiring of the ground signal at the programming pins of the FAC 1 (1CC1)


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
AMM 22-66-34-000-002 Removal of the FAC (1CC1,1CC2)
 AMM 22-66-34-400-002 Installation of the FAC (1CC1,1CC2)
 AMM 22-96-00-710-001 Operational Test of the AFS
 ASM 22-67/01

 3. Fault Confirmation
__________________
 A. Test
 (1) Do the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001) and read the result for the FAC 1.
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message AFS : FAC1/PARITY PIN PRG:
 - replace the FAC-1 (1CC1), (Ref. AMM TASK 22-66-34-000-002) and (Ref. AMM TASK 22-66-34-400-002).
 (1) If the fault continues:
 - do a check and repair the wiring of the ground signal at the programming pins of the FAC 1 (1CC1), (Ref. ASM 22-67/01).
 B. Do the test given in Para. 3.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞22-66-00∞∞∞∞∞∞∞∞∞∞Page 233
 201-299, 401-499, Aug 01/05 CES Loss of the Parity Pin Program on the FAC 2


 1. Possible Causes
_______________
 - FAC-2 (1CC2)

 - wiring of the ground signal at the programming pins of the FAC 2 (1CC2)


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 22-66-34-000-002 Removal of the FAC (1CC1,1CC2)
 AMM 22-66-34-400-002 Installation of the FAC (1CC1,1CC2)
 AMM 22-96-00-710-001 Operational Test of the AFS
 ASM 22-67/01

 3. Fault Confirmation

__________________
 A. Test
 (1) Do the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001) and read the result for the FAC 2.
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message AFS : FAC2/PARITY PIN PRG:
 - replace the FAC-2 (1CC2), (Ref. AMM TASK 22-66-34-000-002) and (Ref. AMM TASK 22-66-34-400-002).
 (1) If the fault continues:
 - do a check and repair the wiring of the ground signal at the programming pins of the FAC 2 (1CC2), (Ref. ASM 22-67/01).
 B. Do the test given in Para. 3.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞22-66-00∞∞∞∞∞∞∞∞∞∞Page 234
 201-299, 401-499, Aug 01/05 CES


R **ON A/C ALL
 TASK 22-66-00-810-833
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 AUTO FLIGHT 自动飞行2(10)