- after 15 seconds, close this circuit breaker
- after 1 minute, do the Ground Scanning of the AFS (Ref. AMM TASK 22-91-00-710-001) and the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001).
(1) If the fault continues:
- replace the FAC-1 (1CC1) (Ref. AMM TASK 22-66-34-000-002) and (Ref. AMM TASK 22-66-34-400-002).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-66-00∞∞∞∞∞∞∞∞∞∞Page A205
May 01/04R
CES FAC 2 Inoperative
1. Possible Causes
_______________
- FAC-2 (1CC2)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 22-66-34-000-002 Removal of the FAC (1CC1,1CC2)
AMM 22-66-34-400-002 Installation of the FAC (1CC1,1CC2)
AMM 22-91-00-710-001 Ground Scanning of the AFS
AMM 22-96-00-710-001 Operational Test of the AFS
3. Fault Confirmation
__________________
A. Test
(1) Do the Ground Scanning of the AFS (Ref. AMM TASK 22-91-00-710-001).
4. Fault Isolation
_______________
A. Table of the circuit breakers used in this procedure:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
121VU AUTO FLT/FAC2/28VDC 5CC2 M19
B. If the test gives the maintenance message AFS : CHECK FAC 2:
- open the circuit breaker 5CC2
- after 15 seconds, close this circuit breaker
- after 1 minute, do the Ground Scanning of the AFS (Ref. AMM TASK 22-91-00-710-001) and the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001).
(1) If the fault continues:
- replace the FAC-2 (1CC2) (Ref. AMM TASK 22-66-34-000-002) and (Ref. AMM TASK 22-66-34-400-002).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-66-00∞∞∞∞∞∞∞∞∞∞Page A206
May 01/04R
CES Loss of the Data between the FAC 1 and the FMGC 1
1. Possible Causes
_______________
- FAC-1 (1CC1)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 22-66-34-000-002 Removal of the FAC (1CC1,1CC2)
AMM 22-66-34-400-002 Installation of the FAC (1CC1,1CC2)
AMM 22-91-00-710-001 Ground Scanning of the AFS
AMM 22-96-00-710-001 Operational Test of the AFS
3. Fault Confirmation
__________________
A. Test
(1) Do the Ground Scanning of the AFS (Ref. AMM TASK 22-91-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message AFS: FAC1/FMGC1 ARINC LK:
- replace the FAC-1 (1CC1) (Ref. AMM TASK 22-66-34-000-002) and (Ref. AMM TASK 22-66-34-400-002).
(1) If the fault continues:
- do the operational test of the AFS (Ref. AMM TASK 22-96-00-710-
001). R
R (a) If the test gives a different message, do the trouble shooting R procedure related to the maintenance message.
Loss of the Data between the FAC 2 and the FMGC 1
1. Possible Causes
_______________
- FAC-2 (1CC2)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 22-66-34-000-002 Removal of the FAC (1CC1,1CC2)
AMM 22-66-34-400-002 Installation of the FAC (1CC1,1CC2)
AMM 22-91-00-710-001 Ground Scanning of the AFS
AMM 22-96-00-710-001 Operational Test of the AFS
3. Fault Confirmation
__________________
A. Test
(1) Do the Ground Scanning of the AFS (Ref. AMM TASK 22-91-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message AFS: FAC2/FMGC1 ARINC LK:
- replace the FAC-2 (1CC2) (Ref. AMM TASK 22-66-34-000-002) and (Ref. AMM TASK 22-66-34-400-002).
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 AUTO FLIGHT 自动飞行2(35)