A. Test
(1) Do the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001) and read the result for the FMGC 1 and the FMGC 2.
4. Fault Isolation
_______________
A. If the test only gives the maintenance message AFS : MCDU1 (FW
DISC)/FMGC1:
- replace the FMGC-1 (1CA1) (Ref. AMM TASK 22-83-34-000-001) and (Ref. AMM TASK 22-83-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring of the MCDU OWN FAIL discrete from the FMGC 1 (1CA1) to the first terminal block (Ref. ASM 22-85/04).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-82-00∞∞∞∞∞∞∞∞∞∞Page 211
Feb 01/98 CES
B. If the test only gives the maintenance message AFS : MCDU 1 (FW DISC)/FMGC2:
- replace the FMGC-2 (1CA2) (Ref. AMM TASK 22-83-34-000-001) and (Ref. AMM TASK 22-83-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring of the MCDU OPP FAIL discrete from the FMGC 2 (1CA2) to the first terminal block (Ref. ASM 22-85/04).
C. If the test gives the two maintenance messages AFS : MCDU1 (FW DISC)/ FMGC1 and AFS : MCDU1 (FW DISC)/FMGC2:
- replace the MCDU-1 (3CA1) (Ref. AMM TASK 22-82-12-000-001) and (Ref. AMM TASK 22-82-12-400-002).
(1) If the fault continues:
- do a check and repair the wiring of the MCDU FAIL discrete from the MCDU 1 (3CA1) to the first terminal block (Ref. ASM 22-85/04).
D. Do the test given in Para. 3.
Loss of the MCDU 2 FAIL Discrete
1. Possible Causes
_______________
- FMGC-1 (1CA1)
- FMGC-2 (1CA2)
- MCDU-2 (3CA2)
- wiring of the MCDU OPP FAIL discrete from the FMGC 1 (1CA1) to the first terminal block
- wiring of the MCDU OWN FAIL discrete from the FMGC 2 (1CA2) to the first terminal block
- wiring of the MCDU FAIL discrete from the MCDU 2 (3CA2) to the first terminal block
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 22-82-12-000-001 Removal of the MCDU (3CA1,3CA2,3CA3)
AMM 22-82-12-400-002 Installation of the MCDU (3CA1,3CA2,3CA3)
AMM 22-83-34-000-001 Removal of the FMGC (1CA1,1CA2)
AMM 22-83-34-400-001 Installation of the FMGC (1CA1,1CA2)
AMM 22-96-00-710-001 Operational Test of the AFS
ASM 22-85/04
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the AFS (Ref. AMM TASK 22-96-00-710-001) and read the result for the FMGC 1 and the FMGC 2.
4. Fault Isolation
_______________
A. If the test only gives the maintenance message AFS : MCDU2 (FW
DISC)/FMGC1:
- replace the FMGC-1 (1CA1) (Ref. AMM TASK 22-83-34-000-001) and (Ref. AMM TASK 22-83-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring of the MCDU OPP FAIL discrete from the FMGC 1 (1CA1) to the first terminal block (Ref. ASM 22-85/04).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-82-00∞∞∞∞∞∞∞∞∞∞Page 213
Feb 01/98 CES
B. If the test only gives the maintenance message AFS : MCDU 2 (FW DISC)/FMGC2:
- replace the FMGC-2 (1CA2) (Ref. AMM TASK 22-83-34-000-001) and (Ref. AMM TASK 22-83-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring of the MCDU OWN FAIL discrete from the FMGC 2 (1CA2) to the first terminal block (Ref. ASM 22-85/04).
C. If the test gives the two maintenance messages AFS : MCDU2 (FW DISC)/FMGC1 and AFS : MCDU2 (FW DISC)/FMGC2:
- replace the MCDU-2 (3CA2) (Ref. AMM TASK 22-82-12-000-001) and (Ref. AMM TASK 22-82-12-400-002).
(1) If the fault continues:
- do a check and repair the wiring of the MCDU FAIL discrete from the MCDU 2 (3CA2) to the first terminal block (Ref. ASM 22-85/04).
D. Do the test given in Para. 3.
Loss of Communication with the FMGC 1 through the MCDU 1