- repair the above wiring.
(b) If there is continuity:
- do a check and repair the wiring of the 28VDC and GND FAC discretes (from the FAC 1 (1CC1) to the FLT CTL/FAC 1 pushbutton switch (12CC1)), (Ref. ASM 22-65/01).
C. If the two tests do not give the maintenance message:
- replace the FAC 1 (1CC1) (Ref. AMM TASK 22-66-34-000-002) and (Ref. AMM TASK 22-66-34-400-002).
(1) If the fault continues:
- replace the RELAY-FAC1 ENGAGED (11CC1).
(2) If the fault continues:
- do a check and repair the wiring of the FAC ENGD COM and FAC ENGD MON discretes (from the FAC 1 (1CC1) to the FAC 1 ENGAGED relay (11CC1)) (Ref. ASM 22-65/01).
D. Do the test given in Para. 3.A.1.(b).
FAC 2 FAULT Legend Comes on without ECAM Warning
1. Possible Causes
_______________
- FAC-2 (1CC2)
- wiring of the FAC ENGD SW COM and FAC ENGD SW MON discretes (from the FAC 2 (1CC2) to the FLT CTL/FAC 2 pushbutton switch (12CC2))
- wiring of the 28VDC and GND FAC discretes (from the FAC 2 (1CC2) to the FLT CTL/FAC 2 pushbutton switch (12CC2))
- RELAY-FAC2 ENGAGED (11CC2)
- wiring of the FAC ENGD COM and FAC ENGD MON discretes (from the FAC 2 (1CC2) to the FAC 2 ENGAGED relay (11CC2))
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 22-66-34-000-002 Removal of the FAC (1CC1,1CC2)
AMM 22-66-34-400-002 Installation of the FAC (1CC1,1CC2)
AMM 22-96-00-710-001 Operational Test of the AFS
ASM 22-65/01
3. Fault Confirmation
__________________
A. Test
(1) Do the operational tests of the AFS (Ref. AMM TASK 22-96-00-710-001) and read the result for the FAC 2:
(a) with the FLT CTL/FAC 2 pushbutton switch (12CC2) released.
(b) with the FLT CTL/FAC 2 pushbutton switch (12CC2) pushed.
4. Fault Isolation
_______________
A. If only the first test gives the maintenance message AFS: FAC2/P-B SW 12CC2:
- replace the FAC-2 (1CC2), (Ref. AMM TASK 22-66-34-000-002) and (Ref. AMM TASK 22-66-34-400-002).
(1) If the fault continues:
- do a check and repair the wiring of the FAC ENGD SW COM and FAC ENGD SW MON discretes (from the FAC 2 (1CC2) to the FLT CTL/FAC 2 pushbutton switch (12CC2)), (Ref. ASM 22-65/01).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞22-66-00∞∞∞∞∞∞∞∞∞∞Page 241
Feb 01/98 CES
B. If only the second test gives the maintenance message AFS: FAC2/P-B SW 12CC2:
- replace the FAC 2 (1CC2) (Ref. AMM TASK 22-66-34-000-002) and (Ref. AMM TASK 22-66-34-400-002).
(1) If the fault continues:
- do a check of the wiring of the FAC ENGD SW COM and FAC ENGD SW MON discretes (from the FAC 2 (1CC2) to the FLT CTL/FAC 2 pushbutton switch (12CC2)) (Ref. ASM 22-65/01).
(a) If there is no continuity:
- repair the above wiring.
(b) If there is continuity:
- do a check and repair the wiring of the 28VDC and GND FAC discretes (from the FAC 2 (1CC2) to the FLT CTL/FAC 2 pushbutton switch (12CC2)), (Ref. ASM 22-65/01).
C. If the two tests do not give the maintenance message:
- replace the FAC 2 (1CC2) (Ref. AMM TASK 22-66-34-000-002) and (Ref. AMM TASK 22-66-34-400-002).
(1) If the fault continues:
- replace the RELAY-FAC2 ENGAGED (11CC2).
(2) If the fault continues:
- do a check and repair the wiring of the FAC ENGD COM and FAC ENGD MON discretes (from the FAC 2 (1CC2) to the FAC 2 ENGAGED relay (11CC2)) (Ref. ASM 22-65/01).
D. Do the test given in Para. 3.A.1.(b).
FAC 1 FAULT Legend does not Come on with ECAM Warning
1. Possible Causes
_______________
- wiring of the 5VAC signal at FLT CTL/FAC 1 pushbutton switch (12CC1)
- P/BSW-FLT CTL/FAC1 (12CC1)
- wiring of FLT CTL/FAC 1 pushbutton switch (12CC1)
- RELAY-FAC1 ENGAGED (11CC1)
- wiring of the FAC 1 ENGAGED relay (11CC1)