R 1EFF : 051-052, 1 52-32-21Page 411 1 1 May 01/05 1 1 1CES 1
R Subtask 52-32-21-865-053
R B. Open, safety and tag this(these) circuit breaker(s):
R -------------------------------------------------------------------------------
R PANEL DESIGNATION IDENT. LOCATION
R -------------------------------------------------------------------------------
R 121VU HYDRAULIC/HYD POWER/Y 3803GX N30
R 122VU DOORS/CARGO 1MJ T12
R 123VU Y HYD/ELEC/PUMP 3802GX AB06
R 123VU Y HYD/ELEC/ELEC PUMP/NORM 3801GX AB03
R 4. Procedure_________
R Subtask 52-32-21-020-051
R A. Removal of the Handle Flap Mechanism
R (Ref. Fig. 402/TASK 52-32-21-991-002)
R (1) Disconnect the spring (6) from the special bolt (7).
R (2) Remove the screws (8) from the handle flap mechanism (9).
R (3) Remove the handle flap mechanism (9) from the door structure (10).
R 1EFF : 051-052, 1 52-32-21Page 412 1 1 May 01/05 1 1 1CES 1
R Handle Flap Mechanism
R Figure 402/TASK 52-32-21-991-002
R 1EFF : 051-052, 1 52-32-21 Page 413
1 1 May 01/05
1 1
1CES 1
R TASK 52-32-21-400-002 R Installation of the Handle Flap Mechanism R 1. Reason for the Job
__________________ R Self Explanatory R 2. Job Set-up Information
______________________ R A. Fixtures, Tools, Test and Support Equipment R -------------------------------------------------------------------------------
R REFERENCE QTY DESIGNATION R -------------------------------------------------------------------------------R No specific access platform 3.5 m (11 ft. 6 in.)
R B. Consumable Materials R -------------------------------------------------------------------------------R REFERENCE DESIGNATION R -------------------------------------------------------------------------------
R Material No. 09-013 R R R Material No. 15-005 R R R Material No. 15-006 R R R Material No. 19-010 R R USA MIL-PRF-81733 TYPE I CLASS A CORROSION INHIBITING BRUSH CONSISTENCY (Ref. 20-31-00) AIB TN 10138 TYPE I GRADE 2 CORROSION PREVENTIVE TEMPORARY PROTECTIVE COMPOUND (Ref. 20-31-00) AIB TN 10138 TYPE I GRADE 3 CORROSION PREVENTIVE TEMPORARY PROTECTIVE COMPOUND (Ref. 20-31-00) USA AMS 5687 LOCKWIRE STAINLESS STEEL ANNEALED 0.8MM DIA (Ref. 20-31-00)
R 1EFF : 051-052, 1 52-32-21Page 414 1 1 May 01/05 1 1 1CES 1R C. Referenced Information
R -------------------------------------------------------------------------------R REFERENCE DESIGNATION R -------------------------------------------------------------------------------
R 12-22-52-640-002 R R 52-30-00-860-001 R R 52-30-00-860-002 R R 52-31-11-820-002
R 3. Job Set-up
__________
R Subtask 52-32-21-860-051 Lubrication of the FWD and AFT Cargo-Compartment Doors Open the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump Close the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump Adjustment of the Door Mechanism
R A. Aircraft Maintenance Configuration
R (1) Make sure that the AFT cargo-compartment door (referred to as cargo R door)is opened and safetied with the actuator safety locks (Ref. TASK R 52-30-00-860-001).
R (2) Make sure that the access platform in position below the opened cargo R door.
R (3) Make sure that the access panel 826AR is removed.
R Subtask 52-32-21-865-054
R B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and R tagged
R -------------------------------------------------------------------------------R PANEL DESIGNATION IDENT. LOCATION R -------------------------------------------------------------------------------R 121VU HYDRAULIC/HYD POWER/Y 3803GX N30 R 122VU DOORS/CARGO 1MJ T12 R 123VU Y HYD/ELEC/PUMP 3802GX AB06 R 123VU Y HYD/ELEC/ELEC PUMP/NORM 3801GX AB03
R 1EFF : 051-052, 1 52-32-21Page 415 1 1 May 01/05 1 1 1CES 1
R 4. Procedure_________
R Subtask 52-32-21-560-051
R A. Preparation of the Replacement Components
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM DOORS 舱门5(78)