1EFF : 001-049, 051-099, 101-149, 201-299, 1 52-32-11Page 622 1301-399, 1Aug 01/05 1 1 1CES 1 1EFF : 001-049, 051-099, 101-149, 201-299, 1 52-32-11Page 623 1301-399, 1Aug 01/05 1 1 1CES 1 TASK 52-32-11-200-006
R R - if the scratch is more than the limit, repair the defective fitting (Ref. SRM 52-30-00) or replace it (Ref. CMM 52-31-12).
(b) If you find a crack, repair it immediately (Ref. SRM 51-73-00).
R R (c) If you find corrosion: - measure the dimensions of the area thta has corrosion (Ref. SRM 52-30-00) - repair the damage if it is less than the limit (Ref. SRM 51-74-00).
5. Close-up________
Subtask 52-32-11-865-059
A. Make sure that this(these) circuit breaker(s) is(are) closed: 1MJ, 3801GX, 3802GX, 3803GX
Subtask 52-32-11-410-054
B. Close Access
(1) Make sure that the work area is clean and clear of tool(s) and other items.
(2) Make sure that the cargo door is closed and locked correctly (Ref. TASK 52-30-00-860-002).
(3) Remove the access platform(s).
Detailed Visual Inspection of Locking Hooks and Fork Fittings of the AFT Cargo Compartment Door
1. Reason for the Job
__________________
Refer to the MPD TASK: 523119-01
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s) No specific lint-free cloth No specific masking paper No specific masking tape No specific access platform 3.5 m (11 ft. 6 in.)
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 11-002 USA MIL-PRF-680 DRY CLEANING SOLVENT (VARSOL/WHITE SPIRIT) (Ref. 20-31-00)
Material No. 15-005 AIB TN 10138 TYPE I GRADE 2 CORROSION PREVENTIVE TEMPORARY PROTECTIVE COMPOUND (Ref. 20-31-00)
Material No. 15-006 AIB TN 10138 TYPE I GRADE 3 CORROSION PREVENTIVE TEMPORARY PROTECTIVE COMPOUND (Ref. 20-31-00)
1EFF : 001-049, 051-099, 101-149, 201-299, 1 52-32-11Page 624 1301-399, 1Aug 01/05R 1 1 1CES 1
C. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
51-73-11-300-002 Repair of Minor Damage on Titanium, Forged Aluminum, or Steel Components 51-75-12-300-001 Repair of Major Paint Damage on Light Alloy and Composite Material 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump 52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump 52-31-21-000-001 Removal of the Locking Handle Mechanism 52-31-21-000-007 Removal of the Locking Unit 52-32-21-000-007 Removal of the Locking Unit 52-32-21-000-013 Removal of the Latching Unit SRM 51-73-00 SRM 51-74-00 SRM 52-30-00
**ON A/C 001-049, 053-099, 101-105, 201-220,
52-32-11-991-021-A Fig. 603
**ON A/C 051-052,
52-32-11-991-021 Fig. 603A
**ON A/C 106-149, 221-299, 301-399,
52-32-11-991-021-B Fig. 603B
1EFF : 001-049, 051-099, 101-149, 201-299, 1 52-32-11Page 625 1301-399, 1Aug 01/05R 1 1 1CES 1
**ON A/C 001-049, 051-099, 101-149, 201-299, 301-399,
3. Job Set-up
__________ Subtask 52-32-11-010-055
A. Get Access
(1)
Remove the access panel 826AR to get access to the locking mechanism of the cargo door.
(2)
Open the cargo door and safety it with the actuator safety locks (Ref. TASK 52-30-00-860-001).
(3) Put the access platform in position below the opened cargo door. Subtask 52-32-11-865-060
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM DOORS 舱门5(49)