4. Procedure
_________ (Ref. Fig. 604/TASK 52-22-11-991-009) Subtask 52-22-11-210-055
A. General Visual Inspection Procedure of the LH/RH Aft Emergency Exit
(1)
Clean the component interface and/or the adjacent area.
(2)
Examine the external surface of the aft emergency exit for scratches and dents to the surface protection.
(a)
If you find scratches, dents or other damage:
-Find the dimensions of the damage and the allowable damage limits (Ref. ASRM 52200010100).
(b)
If you find damage to the surface protection only, repair it (Ref. TASK 51-75-12-300-001) or (Ref. TASK 51-75-12-300-003), as necessary.
5. Close-up
________ Subtask 52-22-11-942-052
A. Remove the access platform(s).
1EFF : 301-399, 1 52-22-11Page 622 1 1 May 01/04 1 1 1CES 1
Aft Emergency-Exit External Surface
Figure 604/TASK 52-22-11-991-009
1EFF : 301-399, 1 52-22-11 Page 623
1 1 May 01/04
1 1
1CES 1
TASK 52-22-11-200-008
General Visual Inspection of Door Stop Assemblies and Locking Hook on Aft Emergency Exit Doors, LH/RH
1.
Reason for the Job
__________________
Refer to the MPD TASK: 522206-01
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific 1 ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
52-22-00-010-001 Opening of the Emergency Exit Doors from the Passenger Compartment 52-22-00-410-001 Closing of the Emergency Exit Doors from the
Passenger Compartment ASRM 52200010100 52-22-11-991-010 Fig. 605
3. Job Set-up
__________ Subtask 52-22-11-010-058
A. Get Access
(1)
Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at the Aft emergency exit door 834 (844).
(2)
Open the Aft emergency exit door 834 (844) (Ref. TASK 52-22-00-010-001).
1EFF : 301-399, 1 52-22-11Page 624 1 1 May 01/04 1 1 1CES 1
4. Procedure
_________
(Ref. Fig. 605/TASK 52-22-11-991-010) Subtask 52-22-11-210-056
A. General Visual Inspection Procedure
(1)
Clean the component interface and/or the adjacent area.
(2)
Examine the locking hooks for cracks, distortion, fretting, gouges, nicks, scratches, other damage and correct installation.
(a)
If you find cracks, distortion, fretting, gouges, nicks, scratches or other damage:
-Repair the locking hooks, refer to (Ref. ASRM 52200010100).
(b)
Make sure the locking hooks are correctly installed.
(3)
Examine the bushes and bolts of the locking hook mechanisms for cracks, gouges, nicks, scratches, wear or damage and correct installation:
(a)
If you find cracks, gouges, nicks, scratches, wear or other damage:
-Repair the locking hook mechanisms, refer to (Ref. ASRM 52200010100).
(b)
Make sure the bushes and bolts of the locking hook mechanisms are correctly installed.
(4)
Examine the door stop assemblies for cracks, distortion, fretting, gouges, nicks, scratches or other damage and correct installation.
(a)
If you find cracks, distortion, fretting, gouges, nicks, scratches or other damage:
-Repair the door stop assemblies, refer to (Ref. ASRM 52200010100).
(b)
Make sure the door stop assemblies are correctly installed.
1EFF : 301-399, 1 52-22-11Page 625 1 1 May 01/04 1 1 1CES 1
Door Stop Assemblies and Locking Hooks
Figure 605/TASK 52-22-11-991-010
1EFF : 301-399, 1 52-22-11 Page 626
1 1 May 01/04
1 1
1CES 1